Telephone Button Programming
500 Series Programs
1-80
Strata CIX/CTX Telephone Button Programming 11/04
513-04
Abandoned Call
Record Output
FB04
, n,
Hold
n =
1.
Enable
2.
Disable (default)
Enable record generation for abandoned calls. Incoming SMDR must
be turned on. Abandoned call records will be generated whether or
not incoming SMDR has been set.
513-05
Display Transferred
Call Records
FB05
, n,
Hold
,
Hold
n =
1.
Source (default)
2.
Destination
Select whether to charge a transferred call to the source or
destination party.
514
SMDR for OLG
Assignment
514
,
Hold
This command assigns SMDR parameters for OLGs.
514-00
OLG
n,
Hold
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
Specify the OLG for which to set SMDR parameters.
514-01
SMDR Record
Display
FB02
, n,
Hold
n =
1.
Enable (default)
2.
Disable
Enable SMDR Record Display.
514-02
Outgoing Records
FB03
, n,
Hold
,
Hold
n =
1.
Enable (default)
2.
Disable
Enable to generate records for outgoing calls. SMDR Record Display
must be on.
514-03
Outgoing Records
FB03
, n,
Hold
,
Hold
n =
1.
Source (default)
2.
Destination
Enable to apply the SMDR record of a transferred call to its source or
its destination.
515
View BIOU Control
Relay Assignment
515
,
Hold
This assignment is used to view functions of the four control relays on
each BIOU PCB set in Program 105 12 Night Relay and 18 Night Bell
Relay; Program 508 Door Lock Control Assignment; and Program
503 19 BGM Mute Relay. The system allows up to two BIOU PCBs to
provide a total of eight control relays. The control relays can be
configured as an external BGM mute control, Night Bell control, Night
Mode Control, and Door Lock Control.
Notes
•
BIOU-1 relays are identified as Control Relays 1~4.
•
BIOU-2 relays are identified as Control Relays 5~8.
515-00
BIOU (1 or 2)
n,
Hold
n =
1 or 2
Enter the BOIU PCB number.
Note
BIOU 1 and BIOU 2 are assigned in Program 100 - Card
Assignment.
515-01
BIOU Relay 1 or 5
FB01
, n,
Hold
n =
1.
Not Use (default)
2.
Ext Paging
3.
Night Bell
4.
Night Relay
5.
Door Lock
View the function of BIOU1, control relay 1 or BIOU2, control relay 5:
View the function of BIOU1, control relay 2 or BIOU2, control relay 6:
View the function of BIOU1, control relay 3 or BIOU2, control relay 7:
View the function of BIOU1, control relay 4 or BIOU2, control relay 8:
•
NOT USE ñ if the relay is not used.
•
PAGE MUTE ñ External BGM mute control activates during an
external page (see
).
•
NIGHT BELL ñ Night Bell control activates during the system
Night Mode only when incoming CO lines ring (see
•
NIGHT RELAY ñ Night Mode Control activates continuously
during the system Night Mode (see
•
DOOR LOCK ñ Door Lock Control activates when a telephone's
Door Unlock button is pressed (see
).
515-02
BIOU Relay 2 or 6
FB02
, n,
Hold
515-03
BIOU Relay 3 or 7
FB03
, n,
Hold
515-04
BIOU Relay 4 or 8
FB04
, n,
Hold
,
Hold
Table 1-35
Programs 500~577
(continued)
Button
Sequence
Value(s)