beautypg.com

Toshiba STRATA CIX User Manual

Page 135

background image

System Error Codes

Trunk Programming Error Codes

Strata CIX/CTX Telephone Button Programming 11/04

2-19

Sy
stem

Er
ro

r

C

odes

323

18

FB02

Select the Type of Service for CBC.

33

FB06

The Incoming Line Group entered is invalid.

33

FB07

The Outgoing Line Group entered is invalid.

49

FB02~FB05

The same value is designated to the Type of Service, Facility
Code, Service Parameters, and Network ID fields that
correspond to the same channel group and different line
service index.

49

FB02

The entered values in Channel Group and Index fields are not
valid CBC assignments. Select NODATA in Type of Service
field to delete CBC setting.

49

FB02
FB06

When an INWATS ILG is assigned in ILG field an Out WATS
Type of Service cannot be assigned.

49

FB02
FB06

If OUTWATS service is selected for Type of Service, an OLG
value must be assigned.

49

FB02
FB06

The selected ILG conflicts with an existing ILG number.

49

FB02
FB07

When an Out WATS OLG is assigned in OLG field an INWATS
Type of Service cannot be assigned.

49

FB02
FB07

Make a selection in OLG field.

49

FB02
FB07

The selected OLG conflicts with an existing ILG number.

49

FB08~FB13

The assigned minimum Bch value (Minimum Calls Zones
1~3) exceeds the related (Maximum Calls Zones 1~3)
maximum Bch value.

49

FB08
FB10
FB12

The assigned minimum Bch value (Minimum Calls Zones
1~3) exceeds the related (Maximum Calls Zones 1~3)
maximum Bch value.

323

49

FB08~FB13

The B channel entered is invalid.

49

FB07

The OLG entered does not exist in system.

49

FB06
FB07

The entered ILG/OLG values are not assigned ISDNs.

50

FB02~FB07

Make a Service Type selection for field 02.

52

FB00

The entered channel number conflicts with an existing ISDN
extension(s), etc.

80

FB00

The entered channel group number does not exist in the
system.

82

-

The Channel Group entered does not exist in the system.

82

FB01

The allowable number of assigned channel groups has been
exceeded.

96

-

The number of allowable CBCs has been exceeded.

Program

Code

Occurred

FB

Sub-

parameter

Error Descriptions