300 series programs, 300 series programs -53 – Toshiba STRATA CIX User Manual
Page 57
Telephone Button Programming
300 Series Programs
Strata CIX/CTX Telephone Button Programming 11/04
1-53
T
e
le
phon
e Butt
on
Pr
og
ramm
ing
300 Series Programs
Table 1-26
Programs 300~302
Button
Sequence
Value(s)
Summary
300
Trunk Assignment
300
,
Hold
This command assigns an analog or T1 trunk (line) and its
parameters to the system.
300-00
Line Number
n,
Hold
n =
1~64 (CTX100)
1~96 (CTX670 Basic)
1~264 (CTX670 Exp.)
Enter the Line Number.
300-01
Line Equipment No.
FB01
, xxyyzz,
Hold
xx =
Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
Enter the line equipment number as xxyyzz. Equipment numbers are
required when assigning a new trunk to the system. It can also be
used to display the equipment location of existing trunks.
Example: If the trunk should be connected to an RCOU in cabinet
shelf 5, slot 2, circuit 3, enter 050203.
Cabinet numbers:
•
CTX100 ñ Select 01 for Base and Expansion cabinet.
•
CTX670 ñ Select 01 for Base and 02~07 respectively for each
Expansion cabinet.
Slot numbers:
•
CTX100 ñ Select 01~04 for Base slots and 05~08 for Expansion
slots.
•
CTX670 ñ Select 01~08 for Base slots and 01~10 for Expansion
slots.
yy =
Slot 01~8 (CTX100),
01~10 (CTX670)
zz =
Circuit (01~04)
Ö or zz = T1 Circuit 01~24
(CTX670).
300-02
Incoming Line Group
FB02
, n,
Hold
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
(default = 0)
Assign the trunk to Incoming Line Group. Two-way trunks need to be
members of one incoming and one outgoing line group.
300-03
Outgoing Line Group
FB03
, n,
Hold
n =
0~32 (CTX100)
0~50 (CTX670 Basic)
0~128 (CTX670 Exp.)
(default = 0)
Assign the trunk to Outgoing Line Group. Two-way trunks need to be
members of one incoming and one outgoing line group.
300-04
Dial Mode
FB04
, n,
Hold
n =
1.
Rotary Dial 10PPS
2.
Rotary Dial 20PPS
3.
DTMF (default)
Enter the Dial Mode.
•
DP 10 PPS = Rotary Dial, 10 PPS
•
DP 20 PPS = Rotary Dial, 20 PPS
300-05
Signaling
FB05
, n,
Hold
n =
1.
DID
2.
Loop (default)
3.
Ground
4.
Tie
5.
LP (Japan)
6.
SR (Japan)
7.
ACU (UK)
Enter the signalling type.
300-06
Start Method
FB06
, n,
Hold
n =
1.
Immediate Start
(default)
2.
Timing Start
3.
Wink Start
Enter the Start Method. This setting defines the start protocol method
used between the PSTN and this trunk. For DID/Tie trunks.
300-07
Release Supervision
FB07
, n,
Hold
n =
1.
Received
2.
Not Received (default)
Enable Release Supervision from the CO.
300-08
Answer Supervision
FB08
, n,
Hold
n =
1.
Received
2.
Not Received (default)
Enable Answer Supervision from the CO.
300-09
Trunk Name
n =
Up to 14 digits
Enter the trunk name.
Note
This function is accessible only through CTX WinAdmin.
300-10
External Ring Repeat
FB10
, n,
Hold
n =
1.
Supplied (default)
2.
Not Supplied