beautypg.com

Toshiba STRATA CIX User Manual

Page 59

background image

Telephone Button Programming

300 Series Programs

Strata CIX/CTX Telephone Button Programming 11/04

1-55

T

e

le

phon

e Butt

on

Pr
og
ramm

ing

302-06

Trunk ID Number

FB06

, n,

Hold

n =

0~126

(default = 0)

An identifier must be used as part of the addressing when an ìexplicitî
identified is used to communicate with the PSTN which channel on
which link is used for the given call. This identifier is assigned by the
connected PSTN.

302-07

D Ch Position

FB07

, n,

Hold

n =

1~24

(default = 24)

PRI includes a 64-kbps D-channel (for transfer of signal information).
Select the channel position to be used for D channel signaling.

Note

This field is used only when the span interface speed is 1.5M.
If the span interface speed is 2M the value is fixed at 16.

302-
08~13

Bearer Services:

Speech

3.1 KHz Audio

7 KHz Audio

Unrestr. 64K

Unrestr. 56K

Unrestr. 2x64K

FB08

~

FB13

, n,

Spkr

,

n1,

Hold

n =

1.

Enable

2.

Disable

Enable the Bearer Capabilities allowed for this PRI Trunk channel
group.

n1 =

1.

Channel Number

2.

Slot Map

Select the Channel Method (map) to identify the channels.

Note

In North America, only Channel Number map is used
(Channel Number).

302-
14~18

Bearer Services:

Unrestr. 384K

Unrestr. 1536K

Unrestr. 1920K

Restr. Digital

Video

FB14

~

FB18

, n,

Spkr

,

n1,

Hold

n =

1.

Enable

2.

Disable (default)

The Bearer Capabilities (384k Unrestricted(H0), 1536k
Unrestricted(H11), 1920k Unrestricted, Restricted Digital Info, Trunk
Video, and Unrestricted Multirate) are not used and should remain
disabled.

n1 =

1.

Channel Number B

2.

Channel Number H

3.

Slot Map B

4.

Slot Map H

Select the Channel Method (map) to identify the channels.

Note

In North America, only Channel Number B map is used.

302-19

Bearer Service
Multirate Unrestricted

FB19

, n,

Hold

n =

1.

Enable

2.

Disable (default)

The Bearer Capabilities 384k Unrestricted (H0), 1536k Unrestricted
(H11), 1920k Unrestricted, Restricted Digital Info, Trunk Video and
Unrestricted Multirate are not used and should remain disabled.

302-20

B Ch Selection
Method

FB20

, n,

Hold

n =

1.

Exclusive

2.

Preferred

3.

Any

The method used for selecting an idle ëBí channel and the reaction if
the PSTN indicates the channel is not available needs to be chosen to
originate a call from CTX.

Preferred option is recommended, unless PSTN needs other choice.

302-21

B Ch Selection

FB21

, n,

Hold

n1 =

1.

Forward Cyclic

2.

Backward Cyclic

3.

Forward Terminal

4.

Backward Terminal

The search method for choosing an idle ëBí channel shall also be
specified. Backward Terminal is the normal method with the PSTN
following a Forward Terminal method.

302-22

T1 Time Slot Pattern

FB22

, n,

Hold

n =

1.

Fixed1 (default)

2.

Fixed2

3.

Flexible

1544 Time Slot Pattern.

302-23

E1 Time Slot Pattern

FB23

, n,

Hold

n =

1.

Fixed1 (default)

2.

Fixed2

3.

Flexible

2048 Time Slot Pattern.

302-24

T-Wait Timer

FB24

, n,

Hold

n =

1.

Enable

2.

Disable (default)

Specify whether the T-Wait timer is to be enabled or disabled. This
field is only valid for Natíl ISDN.

302-25

RBT on Incoming Call

FB25

, n,

Hold

n =

1.

Enable (default)

2.

Disable

Enable Ringback Tone when terminating a call. This field is only valid
for Natíl ISDN.

302-26

Network Mode

FB26

, n,

Hold

n =

1.

Master

2.

Slave (default)

Set this span as Master or Slave for Layer 2 of a QSIG PRI. The
opposite value must be set for the node in which this QSIG PRI
terminates. This governs call setup activity and is not related to clock
synchronization.

302-27

Negotiation Priority

FB27

, n,

Hold

n =

1.

Side A (default)

2.

Side B

Sets this span as Side A or Side B for Layer 3 of a QSIG PRI. The
opposite value must be set for the node in which this QSIG PRI
terminates.

Table 1-26

Programs 300~302

(continued)

Button

Sequence

Value(s)

Summary