Toshiba STRATA CIX User Manual
Page 75

Telephone Button Programming
300 Series Programs
Strata CIX/CTX Telephone Button Programming 11/04
1-71
T
e
le
phon
e Butt
on
Pr
og
ramm
ing
321-02
Number Prefix
FB02
, n,
Hold
n =
Up to 10 digits
Enter the prefix telephone number for which a DID number will be
appended to create a User Identified telephone number. This number
may or may not be a billed number, but is used for Caller ID at the
distant end and could be used for returning your call.
321-03
Number Verification
FB03
, n,
Hold
n =
1.
Enable
2.
Disable
Specify whether the number provided should be screened by the
PSTN before the call is to proceed.
321-04
Default Number 2
FB04
, n,
Hold
,
Hold
n =
Up to 10 digits
Enter the second telephone number to use by default when
originating a call. This is the number that the PSTN has registered for
billing purposes. The second number is for BRI only
322
CNIS Presentation
And Special Number
Assignment
322
,
Hold
When calls are sent to the PSTN with Calling Number Identification
Service (CNIS), the CTX can supply special CNIS information as part
of the Setup Message. This program may be used for sending a
unique number based on the source directing the call to the Strata
CTX PRI.
322-00
OLG Number
n,
Hold
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
OLG Number.
322-01
Source Type
FB01
, n,
Hold
n =
1.
Primary DN (0~99999)
2.
Group CO (1~128)
3.
Pooled Line Group
(1~128)
Specify the type of circuit used for outgoing calls: 1- PDN; 2- GCO; 3-
Pooled Line.
322-02
Source Number
FB02
, n,
Hold
n =
Up to 5 digits
GCO and POOL:
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
Specify the number of the source type selected (PDN, GCO or Pooled
Line).
Note
Entries for this field depend on the Destination Type chosen.
There are no default values for this field (default = no value).
•
PDN: 0~99999
•
GCO: 1~128
•
POOL: 1~128
322-03
Special Number
Assignments
FB03
, n,
Hold
,
Hold
n =
Up to 7 digits
Specify the number to be sent when calling out from the source (max.
seven digits). This number is appended to Program 321 FB02.
Note
Destination Type and Destination must be entered before a
DID number can be assigned.
323
CBC Service
323
,
Hold
To accomplish CBC services, each facility needs to be defined, its
related Line Group assigned and minimum and maximum values for
the services provided. These service parameters may be set for three
different time zones, thus allowing fewer or more services of different
types at different times of the day.
323-00
Channel Group
n,
Hold
n =
1~32 (CTX100)
1~48 (CTX670 Basic)
1~128 (CTX670 Exp.)
Enter the Channel Group Number.
323-01
Index
FB01
, n,
Hold
n =
0~32 (CTX100)
0~48 (CTX670 Basic)
0~128 (CTX670 Exp.)
Enter the CBC Service Index, or click one of the following buttons:
•
List ñ view a summary list of programmed Trunks.
•
Create ñ Assign a new Trunk with default settings.
323-02
Type of Service
FB02
, n,
Hold
n =
1.
No Data (default)
2.
POTS
3.
FX
4.
Tie line (Enbloc)
5.
Tie line (Cut throuogh)
6.
Intra LATA Out WATS
7.
Banded Out WATS
8.
Inter LATA Out WATS
9.
INWATS
Select the CBC Service Type.
Note
To delete CBC, set this field to
1: No Data
.
323-03
Facility Code
FB03
, n,
Hold
n =
00~31
Enter the supplied Facility code value from the PSTN. If no data is
entered in this field, any previously entered data is deleted.
Table 1-33
Programs 321~324
(continued)
Button
Sequence
Value(s)
Summary