Isdn trace location, Isdn trace location -102 – Toshiba STRATA CIX User Manual
Page 106
Telephone Button Programming
900 Series Programs
1-102
Strata CIX/CTX Telephone Button Programming 11/04
ISDN Trace Location
This program enables set up of ISDN protocol event trace collection conditions.
Program Number(s): 904
Prerequisite Program:
None
Reference:
None
Access Sequence:
Login to programming mode from your telephone button pad:
Hold ✱#✱#1✱2✱3✱.
At the
PASSWORD=
prompt, Enter your password and press
Hold.
At the
PROG=
prompt enter
904 and press Hold.
At the
EQUIP=
prompt enter the Shelf, Slot and Port numbers.
Notes
•
Shelf, Slot and Circuit number is entered in “XXYYZZ” format where Shelf is a two digit value from
01~07 corresponding to the Strata CTX Cabinet number, Slot is a two digit value from 01~10
corresponding to the Strata CTX Cabinet’s PCB slot number and Circuit is a two digit value from
01~04 corresponding to the Strata CTX PCB Slot’s circuit number.
•
Always use circuit 01 for RPTU.
1. Press
FB01
to run a LLCI Trace. Press the
Scroll
or
Page
button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
2. Press
FB02
and
set CCL3 Trace Level. Press the
Scroll
or
Page
button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
3. Press
FB03
and
set L2L3 Trace Level. Press the
Scroll
or
Page
button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
4. Press
FB04
and
set STATE Trace Level. Press the
Scroll
or
Page
button to view Non, Brief, or
Detailed options. Enter 1~3 to determine Trace Level.
5. Press
FB05
and
set ERRORS Trace Level. Press the
Scroll
or
Page
button to view Non, Brief, or
Detailed options. Enter 1~3 to determine Trace Level.
6. Press
FB06
and
set L2 Trace Level. Press the
Scroll
or
Page
button to view Non, Brief, or Detailed
options. Enter 1~3 to determine Trace Level.
7. Press
Hold
to execute.
8. Press
# # Hold
to return to the
PROG
=
prompt.
9. Enter another program number to continue programming or press
# # Hold
again to exit programming
mode.
FB Name
FB
Summary
Value
LCD Prompt
LLCI
01
Level of collecting LLCI values.
1:None
(no
information)
2:Brief (important
information)
3:Detailled (all
information)
1:NON
2:BRIEF
3:DETAILED
Layer 3
02
Level of collecting Layer 3 messages.
Layer 2 and 3
03
Level of collecting Layer 2 and Layer 3
messages.
State Transitions
04
Level of collecting State Transitions.
Errors
05
Level of collecting errors.
Layer 2 States
06
Level of collecting Layer 2 States.