System Error Codes
Trunk Programming Error Codes
2-18
Strata CIX/CTX Telephone Button Programming 11/04
318
33
FB15
The pause assignment is wrong.
48
FB05 ~
FB10
No incoming destination number is assigned for the required
parameter.
49
FB03
The selected GCO conflicts with an existing ILG number.
49
FB04
The selected Pool Line Group conflicts with an existing ILG
number.
80
FB03
The entered GCO key group does not exist in the system.
82
FB00
The selected ILG number does not exist in the system.
82
FB01
The selected ILG number does not exist in the system. The
number of ILGs exceed the system capacity.
96
FB03
FB04
The number of allowable GCO or POOL key group
assignments has been exceeded.
319
33
FB01~FB03
The destination number entered is wrong.
48
FB01~FB03
The destination number is not assigned.
320
33
FB00
The entered equipment value is invalid.
54
FB01~FB03
The quantity of lines, ISDN channels and PDNs entered
exceeds the number of ports licensed with this processor.
80
FB00
The circuit for the designated PCB must be an assigned ISDN
primary trunk.
321
33
FB00
The OLG entered is out of the range.
80
FB00
The entered OLG number does not exist in the system.
322
33
-
The Group CO or Pool Line Group Destination is out of range
(1~128).
80
FB00
The entered OLG number does not exist in the system.
80
FB01
FB02
The designated extension number does not exist in the
system.
80
FB01
FB02
The entered GCO value does not exist in the system.
80
FB01
FB02
The entered POOL value does not exist in the system.
82
FB00
The OLG entered is out of the range.
96
FB03
The allowable system DID assignments has been exceeded.
Program
Code
Occurred
FB
Sub-
parameter
Error Descriptions