System programming error codes, System programming error codes -2 – Toshiba STRATA CIX User Manual
Page 118

System Error Codes
System Programming Error Codes
2-2
Strata CIX/CTX Telephone Button Programming 11/04
System Programming Error Codes
Program
Code
FB
Sub-
parameter
Error Descriptions
100
33
FB00
The entered Cabinet/Slot value is out of range.
33
FB01
The entered PCB Type is out of range.
33
FB01
In CTX100, the Card Type Code other than ASTU (STU) was
assigned into S109.
33
FB01
In CTX670, the equipment entered is S109 or S110.
In CTX100, the equipment entered is S110.
49
FB01
Deleting a Card (000) ñ Programmed station and/or trunk data
must be deleted before a card can be deleted.
49
FB01
Changing Card Type Code ñ Card Type cannot be changed.
Delete the existing Card Type before entering a new Card
Type.
49
FB01
The designated BIOU is already in use.
49
FB01
IOU card cannot be deleted because the Control Relay is
assigned to that card.
49
FB01
The PCB cannot be assigned to the designated equipment
position.
49
FB01
м004о is not assigned as Card Type Code.
50
FB01
One of the required parameters (PCM Highway, BDKU Type
or TEI Assignment) has not been assigned.
50
FB02
The PCM highway value entered is not applicable for the
desired PCB assignment. PCB parameters are required for
PDKU or BDKU, RDTU, RDSU, RPTU.
50
FB03
The Channel Type value entered is not applicable for the
desired PCB assignment. PCB parameters are required for
PDKU or BDKU, RDTU, RDSU, RPTU.
50
FB04
The TEI Type value entered is not applicable for the desired
PCB assignment. PCB parameters are required for PDKU or
BDKU, RDTU, RDSU, RPTU.
54
FB01
The number of MF2U cards exceeds the system limit.
102
33
FB01
The entered Feature Code is out of range.
33
FB02
The OLG entered is out of range.
49
FB02
An invalid OLG number was entered in OLG Number field
when assigning a Flexible Numbering Feature code of 551.
50
FB02
м0о is not a valid OLG Number.
51
FB00
Flexible Numbering Plan values cannot be repeated. The
value entered cannot be registered (e.g., If 1234 is registered,
123 cannot be registered).
52
FB00
The value entered conflicts with an existing extension and
cannot be registered.
103
-
-
See