Toshiba STRATA CIX User Manual
Page 132

System Error Codes
Trunk Programming Error Codes
2-16
Strata CIX/CTX Telephone Button Programming 11/04
308
33
FB00
The entered equipment value is invalid.
33
FB03
Wrong assignment intervals.
80
FB00
The designated trunk equipment does not exist in the system.
309
33
FB15
The pause assignment is wrong.
48
FB05 ~
FB10
No incoming destination number is entered for the parameter
required.
49
FB00
The entered DID conflicts with an existing wild card PCB. The
allowable number of DID assignments including a wild card
PCB is exceeded.
49
FB03
The selected GCO conflicts with an existing ILG number.
49
FB04
The selected Pool Line Group conflicts with an existing ILG
number.
51
FB00
The entered ILG number does not exist in the system.
51
FB01
The length of entered DID value exceeds the allowable
contract digit number.
80
FB03
The entered GCO key group does not exist in the system.
82
FB01
The selected ILG number does not exist in the system. The
number of ILGs exceed the system capacity.
96
FB03
FB04
The number of allowable GCO or POOL key group
assignments has been exceeded.
98
FB01
The allowable number of DID assignments has been
exceeded.
310
33
FB00
The entered equipment value is invalid.
48
FB01 ~
FB03
No incoming destination number is assigned for the required
parameter.
80
FB00
The entered circuit is not set to support the designated trunk.
311
49
FB01
Although DISA security is set to Necessary, no DISA code
has been assigned.
312
49
FB01
The entered DID number is not assigned to an ILG.
49
The DID Number entered is invalid.
80
DID Number entered does not exist in the system.
82
FB00
The entered ILG number does not exist in the system.
313
33
FB00
The trunk number entered is out of the range.
33
FB00
The entered equipment value is invalid.
49
FB02
FB03
When Signalling Method field is set to CLASS:
•
The Signalling Contents field value must be assigned
•
The CLID Equipment Number Position circuit for the CIU
must be entered.
80
FB00
The entered trunk number does not exist in the system.
Program
Code
Occurred
FB
Sub-
parameter
Error Descriptions