beautypg.com

Move between control file and register file mvc – Texas Instruments TMS320C67X/C67X+ DSP User Manual

Page 240

background image

MVC

Move Between Control File and Register File

3-180

Instruction Set

SPRU733

Move Between Control File and Register File

MVC

Syntax

MVC (.unit) src2, dst

.unit = .S2

Compatibility

C62x, C64x, C67x, and C67x+ CPU

Opcode

31

29

28

27

23

22

18

17

13

12

11

6

5

4

3

2

1

0

creg

z

dst

src2

0 0 0 0 0 x

op

1 0 0 0 s p

3

1

5

5

1

6

1

1

Operands when moving from the control file to the register file:

Opcode map field used...

For operand type...

Unit

Opfield

src2
dst

uint
uint

.S2

00 1111

Description

The src2 register is moved from the control register file to the register file. Valid
values for src2 are any register listed in the control register file.

Register addresses for accessing the control registers are in Table 3−21
(page 3-182).

Operands when moving from the register file to the control file:

Opcode map field used...

For operand type...

Unit

Opfield

src2
dst

xuint
uint

.S2

00 1110

Description

The src2 register is moved from the register file to the control register file. Valid

values for src2 are any register listed in the control register file.

Register addresses for accessing the control registers are in Table 3−21
(page 3-182).