beautypg.com

Omron Programmable Terminals NT31 NT31C User Manual

Page 280

background image

Appendix I

Relationship between System Program and Hardware

276

Combining a -V1 Version and -V2 Version

Hardware

NT31-ST121

j-EV1

NT31C-ST141

j-EV1

NT31-ST121

j-EV2

NT31C-ST141

j-EV2

System program Ver. 2.0

j or Ver. 2.1j

The following functions (new functions supported by the -V2) cannot be used:
S Additional data areas accessible in CS1-series PCs
S The CS1-series high-speed 1:N NT Link
S Interlock function that controls touch switches, numeral inputs, and character string inputs
S Mathematical function
S Device Monitor function
S NT30/620 compatible mode
S Expanded capabilities for label (guide character) displays, including multiple lines of text, ON/OFF switching

displays, numeral memory table displays, and character string memory table displays

System program Ver. 3.0

j

All of the functions described in the Setup Manual and Reference Manual can be used.

*

The system program’s version can be checked from the System Menu.

Combining a -V2 Version and Version without a -V

j Suffix

Hardware

NT31-ST121

j-E

NT31C-ST141

j-E

NT31-ST121

j-EV2

NT31C-ST141

j-EV2

System program Ver. 1.0

j

The following functions cannot be used
S Analogue meter
S High-definition font display
S Installation of system programs using memory unit
S Connection to Mitsubishi PLCs
S Memory link
S Window control from the host
S Multiple display of window screens
S Moving a window
S Additional data areas accessible in CS1-series PCs
S The CS1-series high-speed 1:N NT Link
S Interlock function that controls touch switches,

numeral inputs, and character string inputs

S Mathematical function
S Device Monitor function
S NT30/620 compatible mode
S Expanded capabilities for label (guide character)

displays, including multiple lines of text, ON/OFF
switching displays, numeral memory table displays,
and character string memory table displays

The following functions cannot be used
S Analogue meter
S High-definition font display
S Connection to Mitsubishi PLCs
S Memory link
S Window control from the host
S Multiple display of window screens
S Moving a window
S Additional data areas accessible in CS1-series PCs
S The CS1-series high-speed 1:N NT Link
S Interlock function that controls touch switches,

numeral inputs, and character string inputs

S Mathematical function
S Device Monitor function
S NT30/620 compatible mode
S Expanded capabilities for label (guide character)

displays, including multiple lines of text, ON/OFF
switching displays, numeral memory table displays,
and character string memory table displays

* Installation of system programs using memory unit

is possible

System program Ver. 3.0

j

The following functions cannot be used
S Installation of system programs using memory unit
S High-definition font display

All of the functions described in the Setup Manual and
Reference Manual can be used.

*

The system program’s version can be checked from the System Menu.