For a bar code reader, Appendix a specifications 253 – Omron Programmable Terminals NT31 NT31C User Manual
Page 263
Appendix A
Specifications
253
For a Memory Link , RS-232C Type
Item
Specification
Communications standard
EIA RS-232C
Communications settings
Start-stop synchronization
Communications speed:
1200, 2400, 4800, 9600, 19200, 38400 bps
Data length:
7, 8 bits
Stop bit:
1, 2 bits
Parity:
None, even, odd
Flow control:
None, RS/CS, XON/XOFF
Response:
Presence/absence
Connector
9-pin D-SUB connector (female) (serial port A)
25-pin D-SUB connector (female) (serial port B)
Number of units connected
1:1
Transmission distance
Max. 15 m*
Communications protocol
Memory link
* When using NT-AL001, specification is as follows:
• RS-232C: Max. 2 m
• RS-422A: Max. total length 500 m
For a Memory Link , RS-422A Type
Item
Specification
Communications standard
EIA RS-422A
Communications settings
Start-stop synchronization
Communications speed:
1200, 2400, 4800, 9600, 19200, 38400 bps
Data length:
7, 8 bits
Stop bit:
1, 2 bits
Parity:
None, even, odd
Flow control:
None, XON/XOFF
Response:
Presence/absence
Connector
25-pin D-SUB connector (female) (serial port B)
Number of units connected
1:1
Transmission distance
Max. 500 m*
Communications protocol
Memory link
For a Bar Code Reader
Item
Specification
Communications standard
EIA RS-232C
Communications settings
Start-stop synchronization
Communications speed:
4,800, 9600, 19200 bps
Data length:
7, 8 bits
Stop bit:
1, 2 bits
Parity:
None, even, odd
Flow control:
RS/CS
Connector
9-pin D-SUB connector (female) (serial port A)
Number of units connected
1:1
Transmission distance
Max. 15 m
Communications protocol
Non-protocol mode
Data format
[STX]
Data (0 to 40 bytes)
[ETX]