beautypg.com

Omron Programmable Terminals NT31 NT31C User Manual

Page 19

background image

1-2

Section

Functions of the NT31/NT31C

7

1-2-4 Comparison between NT30/NT30C and NT31/NT31C

Item

NT30/NT30C

NT31/NT31C

Support Tool used

NT-ZJCAT1-EV4 or NT-ZA3AT-EV2

NT-ZJCAT1-EV4

DIP switches

On rear of unit

None (software settings)

Use of B7A unit

Possible

Not possible

Use of memory unit

Not possible

Possible

RS-232C interface

Connector (9-pin) also used as port for
screen data transfer.

- Serial port A connector (also used

for screen data transfer, 9-pin)

- Serial port B connector (for host

communications only, 25-pin)

RS-422A/485 interface

Terminal block

Serial port B (25-pin D-SUB connector)

Replacement backlight

NT30-CFL01/NT30C-CFL01

NT31C-CFL01 (common use)

NT31/NT31C system program data

NT-ZS3AT-EV1
(including system installer)

The system installer and system pro-
gram data are supplied with the Sup-
port Tool.

High-speed 1:N NT Link

Not possible

Possible*

1

Memory Link

System program

Exclusive use by Memory Link

Same as OMRON connection

y

Screen data

Shared with OMRON connection

Exclusive use by Memory Link

LCD contrast adjustment

By a control on the rear of the unit

By touch panel operation

Backlight brightness adjustment

Not possible

By touch panel operation

Number of user-registered screens

Maximum of 2000

Maximum of 3999

Screen data capacity*2

(User program memory)

512 KB

1 MB

Numeral string data

Maximum of 1000

Maximum of 2000

Character string data

Maximum of 1000

Maximum of 2000

Bit data

256

Maximum of 1000

Mathematical tables

None

256 max.
Calculations can be executed
automatically in the PT.

*1

Image data

Maximum of 224

Maximum of 4095

*3

Library data

Maximum of 896

Maximum of 12288

*3

Method for storing numeric values
(numeral memory data and PT status
control area)

Fixed as BCD (binary coded decimal)

Selectable from BCD (binary coded
decimal) or binary

PT status control area size

4 words

5 words (partial change of contents)*

3

PT status notify area size

3 words

2 words (partial change of contents)*

3

Window control area size

None

9 CH*2

Registering continuous screen

Possible

Not possible (Use a screen switchover
as a substitute.)

Lamp/Touch switch labels

Fixed display (1 line only)

- Multiple lines can be displayed

*1

- ON/OFF switching is possible

*1

- Numeral display is possible

*1

- Character string display is possible

*1

Interlock function

None

Operations can be disabled from the
PC by allocating interlock bits to the
corresponding touch switch, numeral
input, or character string input.

*1

Device monitor function

Not possible

Possible

*1