Connecting to the Host’s RS-422A/485 Port
109
CQM1H CPUs or SRM1, set the following communication conditions for the PC
Setup area.
Item
Setting at Host
I/O port
RS-422A
Communication mode
Host link mode
Communications speed
Set the same speed as for the NT31/NT31C.
(*1)
Stop bit
2 stop bits
Parity
Even
Data length
ASCII 7 bits
Unit #
00
*1 Set the host link communications speed at 9600 bps or 19200 bps with the
Comm. Speed at the NT31/NT31C. For details, refer to Setting the Host Link
Method (page 158).
Set the PC Setup area settings directly from a Programming Device (e.g. CX-
Programmer).
For details on operations relating to the PC Setup area, refer to the manual for
the PC which is used.
The PC Setup area word numbers and settings to be made depending on the
unit to which the connection is made are shown below.
When using port A of the communication board of C200HX/HG/HE(-Z)E
Word #
Writing Value
Settings
DM6555
0001
Host link mode, no CTS control
Communication conditions set by the contents of DM
DM6556
0303
Data length 7 bits, 2 stop bits, even parity,
communications speed: 9600 bps
0304
Data length 7 bits, 2 stop bits, even parity,
communications speed: 19200 bps
DM6558
0000
Unit # 00
When using a CPM1, CPM2A, CPM2C, SRM1
Word #
Writing Value
Settings
DM6650
0001
Host link mode, no CTS control
Communication conditions set by the contents of DM
DM6651
0303
Data length 7 bits, 2 stop bits, even parity,
communications speed: 9600 bps
0304
Data length 7 bits, 2 stop bits, even parity,
communications speed: 19200 bps
DM6653
0000
Unit # 00
When using a CQM1H
Word #
Writing Value
Settings
DM6550
0001
Host link mode, no CTS control
Communication conditions set by the contents of DM
DM6551
0303
Data length 7 bits, 2 stop bits, even parity,
communications speed: 9600 bps
0304
Data length 7 bits, 2 stop bits, even parity,
communications speed: 19200 bps
DM6553
0000
Unit # 00