6-13-1 Compatible Systems

The following table shows the combinations of communications methods and
PCs that can support the PT’s Device Monitor function.

Communications

method

PC model

1:1 NT Link

C200HS-CPU21-E

CPM1-10CDR-

j

*1

C200HS-CPU23-E

CPM1-20CDR-

j

*1

C200HS-CPU31-E

CPM1A-10CD

j-j

*1

C200HS-CPU33-E

CPM1A-20CD

j-j

*1

C200HE-CPU32 (-Z)E

CPM1A-30CD

j-j

*1

C200HE-CPU42 (-Z)E

CPM1A-40CD

j-j

*1

C200HG-CPU33 (-Z)E

CPM2A-30CD

jj-j

C200HG-CPU43 (-Z)E

CPM2A-40CD

jj-j

C200HG-CPU53 (-Z)E

CPM2A-60CD

jj-j

C200HG-CPU63 (-Z)E

CPM2C-10

jjjjjj-j

*2

C200HX-CPU34 (-Z)E

CPM2C-20

jjjjjj-j

*2

C200HX-CPU44 (-Z)E

CQM1-CPU4

j-EV1

C200HX-CPU54 (-Z)E

CQM1H-CPU21

C200HX-CPU64 (-Z)E

CQM1H-CPU51

C200HX-CPU65-ZE

CQM1H-CPU61

C200HX-CPU85-ZE

SRM1-C02-V2

1:N NT Link

C200HE-CPU32 (-Z)E

CQM1H-CPU21

C200HE-CPU42 (-Z)E

CQM1H-CPU51

C200HG-CPU33 (-Z)E

CQM1H-CPU61

C200HG-CPU43 (-Z)E

SRM1-C02-V2

C200HG-CPU53 (-Z)E

CS1G-CPU42-E(V1)

C200HG-CPU63 (-Z)E

CS1G-CPU43-E(V1)

C200HX-CPU34 (-Z)E

CS1G-CPU44-E(V1)

C200HX-CPU44 (-Z)E

CS1G-CPU45-E(V1)

C200HX-CPU54 (-Z)E

CS1H-CPU63-E(V1)

C200HX-CPU64 (-Z)E

CS1H-CPU64-E(V1)

C200HX-CPU65-ZE

CS1H-CPU65-E(V1)

C200HX-CPU85-ZE

CS1H-CPU66-E(V1)
CS1H-CPU67-E(V1)

*1: A CPM1-CIF01 RS-232C Adapter is required.

*2: Use a Conversion Cable (CPM2C-CN111 or CS1W-CN114/118), CPM1-CIF01

RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to connect to the PC.

6-13-2 Connection Method

The 1:1 NT Link or 1:N NT Link can be used. The connection method is exactly
the same as for the 1:1 NT Link or 1:N NT Link. Refer to Section 4 Connecting to
the Host from the RS-232C Port
or Section 5 Connecting to the Host from the
RS-422A/485 Port
for details on connecting to the PC.

The 1:1 NT Link can be used. The connection method is exactly the same as for
the 1:1 NT Link. Refer to Section 4 Connecting to the Host from the RS-232C
Port
or Section 5 Connecting to the Host from the RS-422A/485 Port for details
on connecting to the PC.

The 1:1 NT Link can be used in all CPUs and the 1:N NT Link can also be used in
-V2 and higher versions of the SRM1. The connection method is exactly the
same as for the 1:1 NT Link or 1:N NT Link. With a CPM1, connect the RS-232C
cable to the peripheral port via a CPM1-CIF01 RS-232C Adapter or
CPM1-CIF11 RS-422A Adapter.

Refer to Section 4 Connecting to the Host from the RS-232C Port or Section 5
Connecting to the Host from the RS-422A/485 Port
for details on connecting to
the PC.

The 1:1 NT Link can be used. The connection method is the same as for the NT
Link (1:1). Connect to the PC’s communications connector with a CPM2C-

CQM1H or
C200HX/HG/HE(-ZE)

CQM1 or C200HS

CPM1, CPM2A, or SRM1

CPM2C