beautypg.com

Hardware, Function block operations, 16) definition of a-d converter accuracy – Renesas 4514 User Manual

Page 59

background image

1-46

HARDWARE

4513/4514 Group User’s Manual

FUNCTION BLOCK OPERATIONS

(15) Notes for the use of A-D conversion 2

Do not change the operating mode (both A-D conversion mode and

comparator mode) of A-D converter with bit 3 of register Q2 while

A-D converter is operating.

When the operating mode of A-D converter is changed from the

comparator mode to A-D conversion mode with the bit 3 of register

Q2, note the following;

• Clear bit 2 of register V2 to “0” to change the operating mode of

the A-D converter from the comparator mode to A-D conversion

mode with the bit 3 of register Q2.

• The A-D conversion completion flag (ADF) may be set when the

operating mode of the A-D converter is changed from the com-

parator mode to the A-D conversion mode. Accordingly, set a

value to register Q2, and execute the SNZAD instruction to clear

the ADF flag.

(16) Definition of A-D converter accuracy

The A-D conversion accuracy is defined below (refer to Figure 30).

• Relative accuracy

Zero transition voltage (V

0T

)

This means an analog input voltage when the actual A-D con-

version output data changes from “0” to “1.”

Full-scale transition voltage (V

FST

)

This means an analog input voltage when the actual A-D con-

version output data changes from “1023” to ”1022.”

Linearity error

This means a deviation from the line between V

0T

and V

FST

of

a converted value between V

0T

and V

FST

.

Differential non-linearity error

This means a deviation from the input potential difference re-

quired to change a converter value between V

0T

and V

FST

by 1

LSB at the relative accuracy.

• Absolute accuracy

This means a deviation from the ideal characteristics between 0

to V

DD

of actual A-D conversion characteristics.

Fig. 30 Definition of A-D conversion accuracy

Vn: Analog input voltage when the output data changes from “n” to “n+1” (n = 0 to 1022)

• 1LSB at relative accuracy

(V)

• 1LSB at absolute accuracy

(V)

V

FST

–V

0T

1022

V

DD

1024

V

DD

V

1022

V

n

V

1

V

0

V

n+1

n+1

n

1022

1023

1

0

b

a

c

Output data

Differential non-linearity error =

Linearity error =

[LSB]

c
a

b–a

a

[LSB]

Actual A-D conversion

characteristics

a: 1LSB by relative accuracy
b: V

n+1

–V

n

c: Difference between ideal V

n

and actual V

n

Zero transition voltage (V

0T

)

Analog voltage

Full-scale transition voltage (V

FST

)

Ideal line of A-D conversion
between V

0

–V

1022

This manual is related to the following products: