beautypg.com

4 serial i/o application example, Application – Renesas 4514 User Manual

Page 148

background image

APPLICATION

2.4 Serial I/O

2-45

4513/4514 Group User’s Manual

(2)

Transmit/receive operation of slave

The transmit data is written into the serial I/O register SI with the TSIAB instruction. When the

TSIAB instruction is executed, the contents of register A are transferred to the low-order bits of
register SI and the contents of register B are transferred to the high-order bits of register SI. At
this time, the S

CK

pin must be at the “H” level.

Serial transfer is started with the SST instruction. However, in Figure 2.4.2 where an external

clock is selected, transfer is not started until the clock is input. When the SST instruction is
executed, the serial I/O transmit/receive completion flag (SIOF) is cleared to “0.”

The microcomputer on the transmitting side is informed that the receiving side is ready to receive.

In the connection example in Figure 2.4.2, this notification is done by pulling the control signal “L”
level.

The transmit data is output from the S

OUT

pin synchronously with the falling edges of the shift

clock.

The transmit data is output bit by bit beginning with the LSB bit of register SI. Each time one bit

is output, the contents of register SI are shifted to one bit position toward the LSB.

Also, the receive data is input from the S

IN

pin synchronously with the rising edges of the shift

clock.

The receive data is input bit by bit to the MSB bit of register SI.

A serial I/O interrupt request occurs when the transmit/receive of data is completed, and the SIOF

flag is set to “1.”

The receive data is taken in within the serial I/O interrupt service routine; or the data is taken in

after examining the completion of the transmit/receive operation with the SNZSI instruction without
using an interrupt.
Also, the SIOF flag is cleared to “0” when an interrupt occurs or the SNZSI instruction is executed.
Make sure that the control signal pin level is “H” after the receive operation is completed.

Note: Repeat steps

through

to transmit or receive multiple data in succession.

2.4.4 Serial I/O application example

(1)

Serial I/O

Outline: The 4513/4514 Group can communicate with peripheral ICs.
Specifications: Figure 2.4.2 Serial I/O connection example.

Figure 2.4.5 shows the master serial I/O setting example, and Figure 2.4.6 shows the slave serial
I/O setting example.