Application, 2 interrupts, Disable interrupts – Renesas 4514 User Manual

Page 127: Stop timer operation, Set timer value, Clear interrupt request, Start timer 4 operation, Enable interrupts, Constant period interrupt execution start

background image

APPLICATION

2.2 Interrupts

2-24

4513/4514 Group User’s Manual

Fig. 2.2.8 Timer 4 constant period interrupt setting example

0

b3

b0

Disable Interrupts

Timer 4 interrupt is temporarily disabled.

Interrupt enable flag INTE

Interrupt control register V2

“0”

All interrupts disabled (DI instruction)

Timer 4 interrupt occurrence disabled
(TV2A instruction)

b3

b0

0 1

Stop Timer Operation

Timer 4, timer 3 and prescaler are temporarily stopped.
Dividing ratio of prescaler is selected.

Timer control register W1

Prescaler stop (TW1A instruction)
Prescaler divided by 16 selected

Timer 3 stop (TW3A instruction)
Prescaler selected for count source

Timer 4 stop (TW4A instruction)
Timer 3 underflow signal selected for count source

b3

b0

0

1

0

Timer control register W3

b3

b0

0

0

0

Timer control register W4

Set Timer Value

Timer 3 and timer 4 count times are set. (The formula is shown

A below.)

Timer 3 reload register R3
Timer 4 reload register R4

“52

16

“F9

16

Timer count value 82 set (T3AB instruction)
Timer count value 249 set (T4AB instruction)

Clear Interrupt Request

Timer 4 interrupt activated condition is cleared.

Timer 4 interrupt request flag T4F “0”

Timer 4 interrupt activated condition cleared
(SNZT4 instruction)

Note when the interrupt request is cleared

When

is executed, considering the skip of the next instruction according to the

interrupt request flag T4F, insert the NOP instruction after the SNZT4 instruction.

b3

b0

0

1

1

Start Timer 4 Operation

Timer 4, timer 3 and prescaler temporarily stopped are restarted.

Timer control register W3

Timer 4 operation start (TW4A instruction)

Timer 3 operation start (TW3A instruction)

Prescaler operation start (TW1A instruction)

b3

b0

1 1

Timer control register W1

✕ ✕

Timer control register W4

b3

b0

0

1

0

b3

b0

1

Enable Interrupts

The timer 4 interrupt which is temporarily disabled is enabled.

Interrupt control register V2

Interrupt enable flag INTE

“1”

Timer 4 interrupt occurrence enabled
(TV2A instruction)
All interrupts enabled (EI instruction)

Constant period interrupt execution start

A The prescaler dividing ratio, time 3 count value and timer 4 count value to make the interrupt occur

every 250 ms are set as follows.

250 ms

(4.0 MHz)

3

16

(82+1)

(249+1)

–1

System clock Instruction

clock

Prescaler
dividing
ratio

Timer 3
count
value

Timer 4
count
value

”: it can be “0” or “1.”