beautypg.com

Input effect setup settings, Sampling procedure, Input effect setup settings sampling procedure – Roland Fantom-S88 User Manual

Page 119: P. 119), 119 sampling

background image

119

Sampling

Sampling

Input Effect Setup Settings

1. Press [INPUT SETTING], and then press [7 (In FX Setup)].

The Input Effect Setup screen appears.

2. Press

or

to move the cursor.

3. Turn the VALUE dial, or press [INC] /[DEC] to set the value.

• Type (Input Effect Type)

Selects the input effect type.

4. Press [EXIT] to return to the previous screen.

In this settings screen, you can edit parameters for the type of
input effect you selected. For details on the parameters that can
be edited, refer to the section “Input effect parameters” within
“Parameter List.”

When you enter the Input Effect Setup screen, the indicator at
the right of the Realtime Control knobs will go out, and the
Realtime Control knobs can be used to edit the MFX parameters.
If you once again press the button located at the right of the
Realtime Control knobs so the indicator is lit, the knobs will
control their original functions. When you exit the Input Effect
Setup screen, the indicator will automatically return to its
previous lit state.

Sampling Procedure

1. Press [SAMPLING/RESAMPLING] to access the Sampling

Menu screen.

fig.SMPL03

fig.SMPL04

The upper part of the screen will show the amount of free
memory. If the free memory reaches 0%, no further sampling is
possible.

2. Press [1 (Sampling)]–[F5 (SOLO)] to select the sampling

mode. The sampling-standby screen will appear.

To cancel, press [8 (Exit)].

* You cannot sample the sound that is output from the OUTPUT B

jacks. You’ll need to set things up so that the sound you want to sample
is output from the OUTPUT A (MIX) jacks.

Sampling mode

Sampling:[1 (Sampling)]

Sample a sound from an external input source.

* Operating the keyboards, pads, sequencer will not play the internal

sound generator.

Re-Sampling:[2 (Re-Sampl)]

Resample the sound of the internal sound generator. The sound
of the external input will not be heard.

* The volume of a phrase that you resample may be less than the volume

of the original phrase. If necessary, execute the Normalize command (p.
130) to raise the volume.

Mix Sampling:[3 (Mix)]

Sample the combined sounds of the internal sound generator
and an external input source.

Auto divide sampling:[4 (Auto Devide)]

Sample an extended source, and automatically divide it into
several samples at silent regions. If the sample contains silence, it
will be divided at that point, and the subsequent portion will be
assigned to the next sample number.

* Operating the keyboards, pads or D Beam controllers will not play the

internal sound generator.

Parameter

Explanation

01: Equalizer

Adjusts the tone of the low-fre-
quency and high-frequency
ranges.

02: Enhancer

Modifies the harmonic content
of the high-frequency range to
add sparkle to the sound.

03: Compressor

Restrains high levels and boosts
low levels to make the overall
volume more consistent.

04: Limiter

Compresses the sound when it
exceeds a specified volume, to
keep distortion from occurring.

05: Noise Suppressor

Suppresses noise during peri-
ods of silence.

06: Center Canceler

Removes the sounds that are lo-
calized at the center of the stereo
input. This is a convenient way
to eliminate a vocal.