78

Chapter

2

File
Menu

900

910

File – Import – Digitizer – One Scan (When VIVID 900/910 is Selected)

Parameters for [File-Import-Digitizer-One Scan-Convert] Dialog Box

Reduction Rate

Selects the reduction rate to be applied when importing the data.
You can select any of the following: “1/1”, “1/4”, “1/9”, “1/16”, or “No polygon”.

Fill Holes

Selects whether the programs fill in holes when importing the data. If the setting is “On”, the pro-
gram will automatically generate points to fill in holes left by missing data.

Remove

Selects which the data the program excludes when carrying out the import. Select from an of the
following: “None”, “Boundary (B.)”, “5deg. & B.”, “10deg. & B.”, “15deg. & B.”, or “20deg. & B.”

None:

Removal is not carried out when importing the data.

Boundary(B.):

The program removes boundary points.

5deg. & B.,10deg. & B., 15deg. & B., 20deg. & B.:

The program removes boundary points, and also removes polygons within the
specified angular range (5°, 10 °, 15°, or 20°) to the view vector

Filter

None: The program does not perform filtering when importing the data.

Noise Filter (N.F.): When importing the data, the points that appear to be noise will be corrected

according to other data.

High Quality (H.Q.): The program filters out unreliable data. (Effective only when importing data

that was scanned using the VIVID 910.)

H.Q & N.F.:

Applies both noise filter and high quality filter. (Effective only when importing
data that was scanned using the VIVID 910.)

Save CDM

Save the images as camera data.

Parameters for [File-Import-Digitizer-One Scan] Dialog Box

Hardware Tab

Auto SCSI ID

Check this checkbox if you want the program to automatically check SCSI connections for VIVID
units. If this checkbox is not checked, the program will recognize VIVID units at specified SCSI IDs
only.

Mounted

• Vertical :

Check this checkbox if using the VIVID unit in vertical orientation.

• Horizontal : Check this checkbox if using the VIVID unit in horizontal orientation.

Apply

When you click the [Apply] button after selecting the serial port and rotating stage, the [Angle]
slidebar becomes effective and stage control is enabled.

Note

If connecting to a SKIDS-60YAW unit, select “CSG-602R(Ver.1.0)” from the pull-down menu. If connect-
ing to a SKIDS-60YAW (Ver. 2.0) unit, select “CSG-602(Ver.2.0)”.

Angle

This slidebar becomes enabled when the program determines that the rotating stage is operating
normally. You can use the slidebar to control the stage’s rotation.