263

Chapter

3

Error

Messages

Error Message (Alphabetically)

Cause

Action

The size of this image is different
from the size of selected image.

The size of the selected image was dif-
ferent from that of the image you tried to
load, due to replacement of textures.

Click the [OK] button to close the mes-
sage dialog box.

There are no points. The element
will be removed. (“File name”)

No data points were contained.

Click the [OK] button to close the mes-
sage dialog box. The element will be
selected.

This element does not have mul-
tiple images.

You attempted to execute the command
on an element that has only a single
image.

Click the [OK] button to close the mes-
sage dialog box.

This Shortcut key about [Com-
mand Name] is an invalid combi-
nation. It will be reset!

The shortcut key combination you at-
tempted to set is not supported by this
command.

Click the [OK] button to close the mes-
sage dialog box.

This Shortcut key about [Com-
mand Name] is exist! Please set
another!

The same shortcut key had already been
assigned when you tried to assign it.

Click the [OK] button to close the mes-
sage dialog box.

This version of scene file is not
supported.

The [Open] button was clicked even
though a scene file saved by the Utility
Software VI-S1 had been selected.

Click the [OK] button to close the mes-
sage dialog box.

Too Small Mesh. We can’t get
enough information for registra-
tion.

Among selected elements, at least one
element that is composed of less than
a certain number of constituent points
exists.

Click the [OK] button to close the mes-
sage dialog box.

Turntable not found.

The rotary stage is not connected to the
digitizer or it is not turned ON.

Click the [OK] button to close the mes-
sage dialog box.

Unknown PC Card
(VIVID 700, VI-700)

The type of memory card is incorrect.

Click the [OK] button to close the mes-
sage dialog box.

Value must be 0 < value < 10000.

A value outside the allowable range was
entered.

Click the [OK] button to close the mes-
sage dialog box.

Value must be –100000 < value <
100000.

A value outside the allowable range was
entered and the OK button was clicked.

Click the [OK] button to close the mes-
sage dialog box.

VIVID busy.

The SCSI command did not complete.

Click the [OK] button to close the mes-
sage dialog box.

VIVID not found.

VIVID (VI) series digitizer is not turned
ON, cables are disconnected, or the
SCSI device driver setting is not correct.

Click the [OK] button to close the mes-
sage dialog box.

“Element name” Zero or few poly-
gons found. Skip making LOD.

The selected element has an excessively
small number of polygons.

Click the [OK] button to close the mes-