beautypg.com

Silent-time, Silent-time -74 – SMC Networks TIGERSWITCH 10/100 User Manual

Page 216

background image

C

OMMAND

L

INE

I

NTERFACE

3-74

Command Usage

• When the logon attempt threshold is reached, the system

interface becomes silent for a specified amount of time before
allowing the next logon attempt. (Use the silent-time
command to set this interval.) When this threshold is reached
for Telnet, the Telnet logon interface shuts down.

• This command applies to both the local console and Telnet

connections.

Example

To set the password threshold to five attempts, enter this
command:

Related Commands

silent-time (3-74)

silent-time

Use this command to set the amount of time the management
console is inaccessible after the number of unsuccessful logon
attempts exceeds the threshold set by the password-thresh
command. Use the no form to remove the silent time value.

Syntax

silent-time seconds
no silent-time

seconds - The number of seconds to disable console
response. (Range: 0-65535; 0: no silent-time)

Default Setting

The default value is no silent-time.

Console(config-line)#password-thresh 5
Console(config-line)#