Show sntp, Clock timezone, Show sntp -73 – SMC Networks SMC TigerStack 1000 SMC8748M User Manual

Page 345: Clock timezone -73

background image

S

YSTEM

M

ANAGEMENT

C

OMMANDS

4-73

Related Commands

Related Commands (4-71)

show sntp

This command displays the current time and configuration settings for the
SNTP client, and indicates whether or not the local time has been properly
updated.

Command Mode

Normal Exec, Privileged Exec

Command Usage

This command displays the current time, the poll interval used for
sending time synchronization requests, and the current SNTP mode
(i.e., unicast).

Example

clock timezone

This command sets the time zone for the switch’s internal clock.

Syntax

clock timezone name hour hours minute minutes {before-utc |

after-utc}

name - Name of timezone, usually an acronym.

(Range: 1-29 characters)

hours - Number of hours before/after UTC. (Range: 1-13 hours)
minutes - Number of minutes before/after UTC.

(Range: 0-59 minutes)

before-utc - Sets the local time zone before (east) of UTC.
after-utc - Sets the local time zone after (west) of UTC.

Console#show sntp
Current time: Dec 23 05:13:28 2002
Poll interval: 16
Current mode: unicast
SNTP status : Enabled
SNTP server 137.92.140.80 0.0.0.0 0.0.0.0
Current server: 137.92.140.80
Console#