Error logger register, Error logger register -27, 4error logger register – Motorola MVME1X7P User Manual
Page 275

Programming Model
http://www.motorola.com/computer/literature
4-27
4
Error Logger Register
SBE
SINGLE BIT ERROR is set when the last error logged
was due to a single-bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code reflects
the bit in error. (Refer to the
section.)
MBE
MULTIPLE BIT ERROR is set when the last error logged
was due to a multiple bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code is
meaningless if MBE is set.
ERA
This bit provides status for a function that is not currently
used in the MCECC sector.
EALT
EALT indicates that the last logging of an error occurred
on a DRAM access by an alternate (MI
∗
not asserted)
local bus master.
ESCRB
ESCRB indicates the entity that was accessing DRAM at
the last logging of a single- or double-bit error. If ESCRB
is 1, it indicates that the scrubber was accessing DRAM.
If ESCRB is 0, it indicates that the local MC680x0 bus
master was accessing DRAM.
ERD
ERD reflects the state of the local bus READ signal pin at
the last logging of a single- or double-bit error. ERD = 1
corresponds to READ = high and ERD = 0 to READ =
low. ERD is meaningless if ESCRB is set.
ADR/SIZ
1st $FFF4305C/2nd $FFF4315C (8-bits)
BIT
31
30
29
28
27
26
25
24
NAME
ERRLOG
ERD
ESCRB
ERA
EALT
0
MBE
SBE
OPER
R/C
R
R
R
R
R
R
R
RESET
0 PLS
0 PLS
0 PLS
0 PLS
0 PLS
X
0 PLS
0 PLS