en | Status | Hardware menu

OMS OMNEO Main Station

01-2021 | 03 | F.01U.380.820

Technical Manual

Bosch Security Systems, LLC

18

Status | Hardware menu

Use the

Hardware

menu to access status information for power supplies, device

temperatures, and clock operation.

Figure 18.1:

Status : Hardware Menu

18.1

Power supplies

The

Power Supplies

menu item displays power supply parameters for the different power

supplies used by the device. OMS self-monitors the power used and if it finds any power
levels outside the recommended operating conditions, an alarm generates.

If the power is within the normal operating range, the entry shows in green (Normal).

If the power is outside the normal operating range, but not in the alarm state, the entry
shows in yellow (Marginal).

If the power is outside the marginal operating range, the value shows in red (Alarm).

i

Notice!

This information is for diagnostic purposes only.

Figure 18.2:

Status | Hardware | Power Supplies Screen

Supply Field

The

Supply

field displays the different power supply voltages.

Voltages include: 5.0 V, 3.3 V, and 24 V.

Voltage Field

The

Voltage

field displays the latest voltage reading.

Min Field

The

Min

field displays the minimum voltage the power supply has recorded.

This value resets at reboot.

Max Field

The

Max

field displays the maximum voltage the power supply has recorded.

This value resets at reboot.

Current Field

The

Current

field displays the latest current reading.

Min Field

The

Min

field displays the minimum current recorded on the power supply.

This value resets at reboot.