2 tif and legacy keypanel cable overview, 3 rj45 ethernet connectors, Tif and legacy keypanel cable overview – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual
Page 23: Rj45 ethernet connectors
OMS OMNEO Main Station
Cables and cable requirements | en
23
Bosch Security Systems, LLC
Technical Manual
01-2021 | 03 | F.01U.380.820
7.2
TIF and legacy keypanel cable overview
Each OMS system has unique requirements for cables, so it is not practical to apply these with
the unit. Most of these cables need to be custom built.
Bosch recommends use of 22AWG, stranded, twisted pair cable for the connections. For most
applications, unshielded cable is adequate. Shielded cable is only required when some
condition in the environment is inducing noise into the intercom system. For legacy keypanels
and the TIF, the cables should have three (3) twisted pairs. To connect 4-wire audio devices,
you need two (2) twisted pair cables.
For additional pinouts, see
1
2
3
4
5
6
7
8
1
2
3
4
5
6
Pair 3
Pair 2
Pair 1
Pair 1
Pair 2
Pair 3
OMS panel port
(AIO connector)
RJ12 cable
Pin
Description
Pin
1
RS485 Data +
1
2
RS485 Data -
3
Audio from Matrix +
2
4
Audio to Matrix +
3
5
Audio to Matrix +
4
6
Audio from Matrix -
5
7
RS485 Data +
6
8
RS485 Data -
Tab. 7.13: OMS panel port (AIO Connector) to RJ12 intercom cable
Refer to
–
7.3
RJ45 Ethernet connectors
Each RJ45 Ethernet connector has two LEDs: