3 rvon, Rvon – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual
Page 100
100
en | Configuration | Network menu
OMS OMNEO Main Station
01-2021 | 03 | F.01U.380.820
Technical Manual
Bosch Security Systems, LLC
The controller and the audio device are tightly coupled. Failure to communicate between the
controller and the audio device may cause unexpected results.
Audio IP Field
Use the
Audio IP
field to enter the IP Address used to transmit and receive audio across the
network.
By default, OMNEO interfaces use link local range addresses and are DHCP enabled. If there is
a DHCP server on the network, it takes an IP Address from the DHCP Server. The controller
and the audio device are tightly coupled and must be in the same subnet. Failure to
communicate between the controller and the audio device may cause unexpected results.
Netmask Field
Use the Netmask
field to enter the netmask address.
Gateway Field
Use the
Gateway
field to enter the gateway address, if applicable.
DNS Server Field
Use the
DNS
Server
field to enter the DNS server address for the OMNEO interface.
Device Field
Use the
Device
field to enter the name of the OMS device used by other OMNEO devices.
Domain Field
Use the
Domain
field to enter the domain in which OMNEO resides. Leave this field blank if
multiple domains are not used. This implies the .local domain is used.
i
Notice!
It is necessary to enter a DNS server address when providing a domain.
Use Static Check Box
Select the
Use Static
check box to determine whether the IP address for the OMNEO interface
is fixed and manually entered.
Use RSTP Check Box
Select the
Use RSTP
check box to determine whether RSTP is used on the port. See
21.3
RVON
Use the
RVON
screen to configure the RVON network interface.
Figure 21.4:
Configuration | Network | RVON
IP Address Field
Use the
IP Address
field to enter the IP address of the RVON Port interface.
i
Notice!
The RVON Port can be on a different network from the OMNEO and Control Port interfaces.