en | Configuration | Network menu

OMS OMNEO Main Station

01-2021 | 03 | F.01U.380.820

Technical Manual

Bosch Security Systems, LLC

The controller and the audio device are tightly coupled. Failure to communicate between the
controller and the audio device may cause unexpected results.

Audio IP Field

Use the

Audio IP

field to enter the IP Address used to transmit and receive audio across the

network.
By default, OMNEO interfaces use link local range addresses and are DHCP enabled. If there is
a DHCP server on the network, it takes an IP Address from the DHCP Server. The controller
and the audio device are tightly coupled and must be in the same subnet. Failure to
communicate between the controller and the audio device may cause unexpected results.

Netmask Field
Use the Netmask

field to enter the netmask address.

Gateway Field

Use the

Gateway

field to enter the gateway address, if applicable.

DNS Server Field

Use the

DNS

Server

field to enter the DNS server address for the OMNEO interface.

Device Field

Use the

Device

field to enter the name of the OMS device used by other OMNEO devices.

Domain Field

Use the

Domain

field to enter the domain in which OMNEO resides. Leave this field blank if

multiple domains are not used. This implies the .local domain is used.

i

Notice!

It is necessary to enter a DNS server address when providing a domain.

Use Static Check Box

Select the

Use Static

check box to determine whether the IP address for the OMNEO interface

is fixed and manually entered.

Use RSTP Check Box

Select the

Use RSTP

check box to determine whether RSTP is used on the port. See

RSTP,

page 67.

21.3

RVON

Use the

RVON

screen to configure the RVON network interface.

Figure 21.4:

Configuration | Network | RVON

IP Address Field

Use the

IP Address

field to enter the IP address of the RVON Port interface.

i

Notice!

The RVON Port can be on a different network from the OMNEO and Control Port interfaces.