beautypg.com

9 intercom configuration, 1 port configuration, 1 connect 2-wire devices to oms – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual

Page 28: Intercom configuration, Port configuration, Connect 2-wire devices to oms, 9intercom configuration

background image

28

en | Intercom configuration

OMS OMNEO Main Station

01-2021 | 03 | F.01U.380.820

Technical Manual

Bosch Security Systems, LLC

9

Intercom configuration

9.1

Port configuration

9.1.1

Connect 2-Wire devices to OMS

i

Notice!

Applicable for Analog, Analog Plus, Intermediate, and Advanced models.

To

connect a 2-Wire device to OMS

, do the following:

1.

Navigate to the

Configuration icon

.

2.

Click the

ENC2 encoder knob

.

The Configuration menu displays.

3.

Navigate to the

Ports icon

.

4.

Click the

ENC2 encoder knob

.

The Ports menu displays.

5.

Navigate to the

2-Wire icon

.

6.

Click the

ENC2 encoder knob

.

The 2-Wire Ports screen displays.

7.

Navigate to the

Mode field

.

8.

Click the

ENC2 encoder knob

.

The Mode field becomes active.

9.

Select the

desired mode

.

10. Press the

ENC2 encoder knob

.

11. Navigate to the

Loop field

. (Optional)

Modifications cannot be made to RTS 1 and RTS 2 modes.

12. Click the

ENC2 encoder knob

.

The field is immediately toggled.

13. Navigate to the

Auto-Mute field

. (Optional)

14. Click the

ENC2 encoder knob

.

The field is immediately toggled.