beautypg.com

7 page change – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual

Page 60

background image

60

en | Basic operation

OMS OMNEO Main Station

01-2021 | 03 | F.01U.380.820

Technical Manual

Bosch Security Systems, LLC

GREEN LED

RED LED

GREY LED

CONTROL
RVON

The link is up.

The Control or RVON
IP Address is
specified, but none of
the links are up (for
RJ45). The LED is red
when and IP address
is defined, but there
is no link.

The LED is grey when
no IP address
(Control or Audio) is
specified but at least
one of the other links
is up.

OMNEO
The status indicators are displayed to mimic the back panel

The link is up.

The Audio and /or
Control interfaces
have an IP Address
but none of the four
links are up.
OR
An SFP is installed
and there is no link.

At least one OMNEO
link is up.
OR
No SFP is installed.

Miscellaneous

The

Miscellaneous

section contains additional status information for Alarms, AZedit sessions,

IPedit sessions, and PTP clock status.

Alarms

X/Y is shown, where X is the number of unacknowledged alarms and
where Y is the total number of active alarms.

When shown in red, X is greater than 0

When shown in yellow, X is equal to 0 and Y is greater than 0

When shown in green, X and Y are equal to 0

AZedit

The number of active AZedit sessions.

When shown in green, there is at least one AZedit connection

When shown in yellow, there are no AZedit connections

IPedit

The number of active IPedit sessions.

When shown in green, there is at least one IPedit connection

When shown in yellow, there are no IPedit connections

CLK

The status of the OMNEO PTP clock.

When a green LED is displayed, the PTP clock is linked

When a red LED is displayed, the PTP clock is not linked

10.7

Page change

The

Page

button provides access to different setup pages on the device. Setup pages provide

a quick method to reconfigure key assignments. There are four setup pages.