en | Basic operation
OMS OMNEO Main Station
01-2021 | 03 | F.01U.380.820
Technical Manual
Bosch Security Systems, LLC
GREEN LED
RED LED
GREY LED
CONTROL
RVON
The link is up.
The Control or RVON
IP Address is
specified, but none of
the links are up (for
RJ45). The LED is red
when and IP address
is defined, but there
is no link.
The LED is grey when
no IP address
(Control or Audio) is
specified but at least
one of the other links
is up.
OMNEO
The status indicators are displayed to mimic the back panel
The link is up.
The Audio and /or
Control interfaces
have an IP Address
but none of the four
links are up.
OR
An SFP is installed
and there is no link.
At least one OMNEO
link is up.
OR
No SFP is installed.
Miscellaneous
The
Miscellaneous
section contains additional status information for Alarms, AZedit sessions,
IPedit sessions, and PTP clock status.
Alarms
X/Y is shown, where X is the number of unacknowledged alarms and
where Y is the total number of active alarms.
–
When shown in red, X is greater than 0
–
When shown in yellow, X is equal to 0 and Y is greater than 0
–
When shown in green, X and Y are equal to 0
AZedit
The number of active AZedit sessions.
–
When shown in green, there is at least one AZedit connection
–
When shown in yellow, there are no AZedit connections
IPedit
The number of active IPedit sessions.
–
When shown in green, there is at least one IPedit connection
–
When shown in yellow, there are no IPedit connections
CLK
The status of the OMNEO PTP clock.
–
When a green LED is displayed, the PTP clock is linked
–
When a red LED is displayed, the PTP clock is not linked
10.7
Page change
The
Page
button provides access to different setup pages on the device. Setup pages provide
a quick method to reconfigure key assignments. There are four setup pages.