3 omneo (rj45), 4 rvon, Omneo (rj45) – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual
Page 83: Rvon, Omneo, Port. see
OMS OMNEO Main Station
Status | Network menu | en
83
Bosch Security Systems, LLC
Technical Manual
01-2021 | 03 | F.01U.380.820
No errors detected
Tx Power Field
The
Tx Power
field displays the amount of power used to transmit the outgoing optical signal.
Rx Power Field
The
Rx Power
field displays the amount of power being received from the incoming optical
signal.
14.3
OMNEO (RJ45)
The
OMNEO (RJ45)
screen is used to view the OMNEO (RJ45) network status.
Figure 14.4:
Status | Network | OMNEO (RJ45)
Link A Column
The
Link
A
column displays the link status, connection speed, and duplex status for the Link A
OMNEO (RJ45) connection.
Link B Column
The
Link B
column displays the link status, connection speed, and duplex status for the Link B
OMNEO (RJ45) connection.
Link Up Field
The
Link Up
field displays the status of data communication on the OMNEO (RJ45) port.
Available statuses are:
The link is up
The link is not up, but an IP address is defined
No IP address is defined
Speed Field
The
Speed
field displays the transmission speed over the OMNEO interface.
The OMNEO interfaces support 100 Mbps and 1 Gbps.
Duplex Field
The
Duplex
field displays the transmit mode the OMNEO network interface is currently
operating.
Almost all Ethernet interfaces auto-negotiate to full duplex. If the interface displays half duplex
mode, this typically signifies the auto-negotiate failed, resulting in network collisions and
errors.
Available options for this field are:
Half-Duplex
Can either transmit or receive, but not both simultaneously
Full-Duplex
Can transmit and receive simultaneously
14.4
RVON
The
RVON
screen is used to view the status of the RVON network status.