en | Alarms menu
OMS OMNEO Main Station
01-2021 | 03 | F.01U.380.820
Technical Manual
Bosch Security Systems, LLC
Alarm Popup
Description
Solution
Check if:
No MAC address defined for
Control port
Depending on which
MAC address is missing,
that network interface
would not be
operational.
–
Power-cycle the OMS.
OMNEO PTP clock
synchronization unlocked
The OMNEO
synchronization clock
was lost.
–
Ensure the OMNEO clock
master is always powered-on.
You can select an OMNEO
device as the "preferred
master" and ensure that
device is always powered-on.
–
Check that the network
switches adhere to the
recommended OMNEO switch
settings. For more
binary/
OMNEONetworkRequirements
AndConsiderations.pdf
.
No OMNEO links are up
None of the four
OMNEO connectors has
network links.
–
There is a bad cable.
–
There is a loose/intermittent
cable connection.
–
The switch or some other
device in the network
powered-off.
OMNEO network interfaces
are on different subnets
OMNEO Control and
Audio interfaces are on
different subnets.
Check the OMNEO network
settings in the menu Configuration
| Network OMNEO:
–
If using static IP addresses,
change one or both of the
addresses so the subnets
match.
–
If using DHCP, check the
DHCP server settings and
ensure OMS and the DHCP
server can communicate on
the network.
–
Power-cycle OMS.
For more information on Subnets
and Network Masks, refer to
.