3 alarm troubleshooting, Alarm troubleshooting – Telex RTS OMS OMNEO Main Station Advanced Digital Partyline Intercom Base (5-Pin Female) User Manual
Page 158
158
en | Alarms menu
OMS OMNEO Main Station
01-2021 | 03 | F.01U.380.820
Technical Manual
Bosch Security Systems, LLC
33.3
Alarm troubleshooting
Alarm Popup
Description
Solution
Check if:
Lost contact with keypanel
Lost contact with
keypanel
–
The device powered off.
–
The device was physically
removed from network (e.g.
bad cable, loose connection,
cable accidentally removed)
or the network configuration
is no longer in the same
network subnet as OMS.
Control Port Ethernet link
down
For each Ethernet
connector, a separate
alarm stating that the
link went down (e.g.
cable accidentally
unplugged).
–
There is a bad cable
–
There is a loose/intermittent
cable connection
–
The switch or some other
device in the network
powered-off.
OMNEO RJ45 Link A Ethernet
link down
A redundant OMNEO
network link went
down.
–
There is a bad cable
–
There is a loose/intermittent
cable connection.
–
The switch or some other
device in the network
powered-off.
Excessive power-ups for
keypanel
A keypanel has
disconnected/
reconnected at an
unusual rate.
–
Power-cycle the device and/or
OMS.
–
Check for bad cabling.
OMNEO audio link failed for
An OMNEO or RVON
audio link went down.
–
The device powered off.
–
The device was physically
removed from network (e.g.
bad cable, loose connection,
cable accidentally removed)
or the network configuration
is no longer in the same
network subnet as OMS.
Keypanel
A keypanel is pressing
keys at an unusual rate.
–
Power cycle the device.
Excessive communication
errors for
Excessive
communication errors in
the keypanel data link.
–
Power cycle the device and/or
OMS.
–
Check for bad cabling.