ProSoft Technology MVI71-DFNT User Manual

Page 37

background image

MVI71-DFNT ♦ PLC 5

Installing and Configuring the Module

EtherNet/IP Client/Server Communication Module

User Manual

ProSoft Technology, Inc.

Page 37 of 175

February 3, 2011

Parameter

Range

Description

Function Code See Command

Function Codes (page

34)

These parameters specify the function to be executed by the command. The

Reference chapter in this manual describes the meaning of these values for

each of the available supported commands. Following is a complete list of the

command supported by the Client driver.
Function Code Listing
Basic Command Set

1

Protected Write

2

Unprotected Read

3

Protected Bit Write

4

Unprotected Bit Write

5

Unprotected Write

PLC-5 Command Set (0x0F)

100

Word Range Write (Binary Address)

101

Word Range Read (Binary Address)

102

Read-Modify-Write (Binary Address)

150

Word Range Write (ASCII Address)

151

Word Range Read (ASCII Address)

152

Read-Modify-Write (ASCII Address)

SLC Command Set (0x0F)

501

Prot Typed Read with 2 addr fields

502

Prot Typed Read with 3 addr fields

509

Prot Typed Write with 2 addr fields

510

Prot Typed Write with 3 addr fields

511

Prot Type Write with Mask 3 addr field

Function

Parameters

See Command

Function Codes (page

34)

The number of auxiliary parameters required depends on the function code

selected for the command.