ProSoft Technology MVI71-DFNT User Manual

Page 154

background image

Reference

MVI71-DFNT ♦ PLC 5

User Manual

EtherNet/IP Client/Server Communication Module

Page 154 of 175

ProSoft Technology, Inc.

February 3, 2011

Set the

R

EAD

/W

RITE

parameter to

W

RITE

.

The module supports a

T

ARGET

D

EVICE

parameter value of

500CPU

or

PLC5.

In order to complete the configuration of

the MSG instruction, select the

S

ETUP

S

CREEN

area of the MSG object. This

displays the following dialog box.

The

T

ARGET

D

EVICE

D

ATA

T

ABLE

A

DDRESS

must be set to a valid file element

(such as, N11:0) for SLC and PLC5 messages. The

M

ULTI

H

OP

option must be

set to

Y

ES

.

The

M

ULTI

H

OP

tab portion of the dialog box must be completed as

displayed in the following window:

Set the IP address value to the module’s Ethernet IP address. You must press

the "Insert" key to add the second line for ControlLogix Backplane and set the

slot number to zero.