ProSoft Technology MVI71-DFNT User Manual
Page 149
MVI71-DFNT ♦ PLC 5
Reference
EtherNet/IP Client/Server Communication Module
User Manual
ProSoft Technology, Inc.
Page 149 of 175
February 3, 2011
Verify that the
CIP
radio-button is selected as the
C
OMMUNICATION
M
ETHOD
. The
P
ATH
specifies the message route from the ControlLogix processor to the DFNT
module. Path elements are separated by commas. In the example path shown,
the first element is "Enet", which is the user-defined name given to the 1756-
ENET module in the chassis (you could substitute the slot number of the ENET
module for the name), the second element, "2", represents the Ethernet port on
the 1756-ENET module, and the last element of the path, "192.168.0.75", is the
IP address of the DFNT module, the target for the message.
More complex paths are possible if routing to other networks using multiple 1756-
ENET modules and racks. Refer to the Rockwell Automation Support
Knowledgebase for more information on Ethernet routing and path definitions.
CIP Data Table Read
CIP data table read messages transfer data to the ControlLogix processor from
the DFNT module. An example rung used to execute a read command is shown:
The
M
ESSAGE
C
ONFIGURATION
dialog box must be completed to define the data
set to transfer to the processor from the module. An example of the dialog box
follows: