5.6.4 Module Specific Error (not DFNT Compliant)

Code (Int)

Code (Hex) Description

-1

0xFFFF

CTS modem control line not set before transmit

-2

0xFFFE

Timeout while transmitting message

-10

0xFFF6

Timeout waiting for DLE-ACK after request

-11

0xFFF5

Timeout waiting for response after request

-12

0xFFF4

Reply data does not match requested byte count

-20

0xFFEC

DLE-NAK received after request

-21

0xFFEB

DLE-NAK sent after response

-200

0xFF38

DLE-NAK received after request