10.0 Using the ME-RTR Router

SETUP

Set Start Gen Volts

OFF

P1A edit AGS Setup

Set Start Gen Volts

11.5 Volts

P1A EDIT AGS Setup

Set Start Gen Volts

15.9 Volts

P1A EDIT AGS Setup

S

...

04A Gen Run VDC

11.5 to 14.4

P1A View AGS Setup

Set Start Volts

Delay = OFF

P1A EDIT AGS Setup

Set Start Volts

Delay = 60 Seconds

P1A edit AGS Setup

Set Start Volts

Delay = 127 Minutes

P1A EDIT AGS Setup

...

Set Stop Voltage

OFF

P1A EDIT AGS Setup

...

Set Stop Voltage

14.4 Volts

P1A edit AGS Setup

Set Stop Voltage

Float

P1A EDIT AGS Setup

S

S

S

Set Stop Volts

Delay = OFF

P1A EDIT AGS Setup

Set Stop Volts

Delay = 60 Seconds

P1A edit AGS Setup

Set Stop Volts

Delay = 127 Minutes

P1A EDIT AGS Setup

...

Set Daily Gen Run

ON

P1A EDIT AGS Setup

04B Gen Run Time

OFF

P1A View AGS Setup

Set Daily Gen Run

OFF

P1A edit AGS Setup

S

S

Set Start Gen Time

8:00am

P1A edit AGS Setup

Set Start Gen Time

12:00pm

P1A EDIT AGS Setup

...

Set Start Gen Time

7:45am

P1A EDIT AGS Setup

S

Set Stop Gen Time

12:00pm

P1A edit AGS Setup

Set Stop Gen Time

12:15am

P1A EDIT AGS Setup

...

Set Stop Gen Time

11:45am

P1A EDIT AGS Setup

Set Gen Start AC

Amps = 5A

P1A EDIT AGS Setup

04C Gen Run Amps

OFF

P1A View AGS Setup

Set Gen Start AC

Amps = OFF

P1A edit AGS Setup

S

Set Amps Start Delay

OFF

P1A EDIT AGS Setup

Set Amps Start Delay

60 Seconds

P1A edit AGS Setup

...

Set Amps Start Delay

127 Minutes

P1A EDIT AGS Setup

S

Set Gen Start AC

Amps = 60A

P1A EDIT AGS Setup

...

Continued on next page

...

...

...

...

S

Set Gen Stop AC Amps

0A

P1A edit AGS Setup

Set Gen Stop AC Amps

60A

P1A EDIT AGS Setup

...

Set Gen Stop AC Amps

10A

P1A EDIT AGS Setup

S

Set Amps Stop Delay

OFF

P1A EDIT AGS Setup

Set Amps Stop Delay

60 Seconds

P1A edit AGS Setup

...

Set Amps Stop Delay

127 Minutes

P1A EDIT AGS Setup

...

...

Start Gen Volts Range: 12-volt = 9.0-15.9 VDC;

24-volt = 18.0-31.8 VDC;

48-volt = 36.0-63.6 VDC

Stop Gen Volts Range: 12-volt = 9.1-16.1 VDC;

24-volt = 18.2-32.2 VDC;

48-volt = 36.4-64.4 VDC

Note: MS-PAE and MS-PE Series models only

...

...

Figure 10-3, AGS Menu Maps in ME-RTR Router (Section 2)