0 using the me-rtr router – Magnum Energy AGS Network (ME-AGS-N) User Manual
Page 85

79
© 2012 Magnum Energy, Inc.
10.0 Using the ME-RTR Router
To manually start the generator and have it automatically stop:
From the AGS Home screen (to access, refer to Section 10.2.1.1):
1. Press the CTRL button.
2. Turn the SELECT knob to the 03 Gen Control menu.
3. Press the SELECT knob. The Set Gen Control menu displays with an arrow
to the right of the current setting.
4. Turn the SELECT knob to the ON setting.
5. Press the SELECT knob to select the ON setting. The selection arrow ap-
pears to the right of the screen. The generator should start at this time.
After the generator is running, rotate the SELECT knob to AUTO (under the
CTRL: 03 Gen Control menu), and then press the SELECT knob to select the
AUTO setting.
Note: When the generator is manually started, and then changed to autos-
top, the SETUP: 04A Gen Run VDC settings are used to determine when the
generator will autostop. If the SETUP: 04A Gen Run VDC is set to OFF, the
Start/Stop Volts Delay and Stop Gen Volts values that were entered prior to
selecting OFF will still be used to autostop the generator.
If the generator does not start or stop as expected, refer to Section 12.0
“ME-AGS-N Remote Troubleshooting” in this manual.
To manually stop the generator:
From the AGS Home screen (to access, refer to Section 10.2.1.1):
1. Press the CTRL button.
2. Turn the SELECT knob to the 03 Gen Control menu.
3. Press the SELECT knob. The Set Gen Control menu displays with an arrow
to the right of the current setting.
4. Turn the SELECT knob to the OFF setting.
5. Press the SELECT knob to select the OFF setting. The selection arrow ap-
pears to the right of the screen. The generator should stop at this time.
If the generator does not stop as expected, refer to Section 12.0 “ME-AGS-N
Remote Troubleshooting” in this manual.
To manually start the generator:
From the AGS Home screen (to access, refer to Section 10.2.1.1):
1. Press the CTRL button.
2. Turn the SELECT knob to the 03 Gen Control menu.
3. Press the SELECT knob. The Set Gen Control menu displays with an ar-
row to the right of the current setting.
4. Turn the SELECT knob to the ON setting.
5. Press the SELECT knob to select the ON setting. The selection arrow ap-
pears to the right of the screen. The generator should start at this time.
If the generator does not start as expected, refer to Section 12.0 “ME-AGS-N
Remote Troubleshooting” in this manual.