beautypg.com

Ags: 08 ags tech menu, 0 using the me-rc remote – Magnum Energy AGS Network (ME-AGS-N) User Manual

Page 41

background image

35

© 2012 Magnum Energy, Inc.

8.0 Using the ME-RC Remote

Info: When the RV mode is used and the AGS system feature is

required, the user will need to re-enable the AGS system each time

the generator is manually turned on or off.

Info: If the AGS is automatically disabled when using RV mode, the

AGS status displays “Lockout”.

• AGS

Rev – Displays the software revision of the connected AGS.

Info: The AGS accessory may display a “0.0” revision for several

reasons. Either the AGS is not installed, there is no communication

because of a bad or miswired network cable, the AGS is not pow-

ered, or the AGS is bad.

• AGS

Mode – This setting allows you to confi gure the AGS to comply

with RVIA standards¹. When the AGS is set to “RV”, the AGS is auto-

matically disabled any time the generator is manually turned on or off.

Select Other if your system is for a RV, or your requirements do not

need the AGS to be disabled should the generator be manually started/

stopped.
Default setting: AGS Mode = RV
Settings: RV, Other

AGS: 08 AGS TECH Menu
This menu displays meter data on the operating condition of the generator

and AGS, and has an AGS mode setting.
• Gen

Run – Displays the number of hours the generator has been cur-

rently running from an autostart condition. This menu does not deter-

mine run time when the generator has been manually started.

• AGS

VDC – Displays the battery voltage currently connected to the AGS

(on Terminals #3 and #4). This voltage is used to power the AGS and is

the voltage reading the 05 Start Volts setting is monitoring to determine

when to start.

• Temp – Displays the current temperature reading of the temperature

sensor and is the temperature the 04 Start Temp F setting is monitoring

to determine when to start. If the temperature sensor is not installed,

the display will either show a very high temperature value (122C/252F),

or “TS open” displays – depending on your remote revision.

Info: This menu is important when determining if the AGS is working

correctly, or for troubleshooting an AGS installation.

Info: For any fault mode displayed in the status menu, please refer

to Section 12.0 “ME-AGS-N Remote Troubleshooting” in this manual.

Note: AGS menus 03-07 were covered in Section 8.1.

Note¹ - RV manufacturers use the NFPA 1192 Standard on Recreational

Vehicles for installing an AGS system. This standard has a requirement that

states when the generator is manually turned on or off, the AGS system

must also be turned off. Selecting the “RV” setting satisfi es this requirement

by automatically disabling the AGS system when it senses that the generator

has been manually turned on or off. In installations where the requirement

to automatically disable the AGS system is not needed, the “Other” setting

can be chosen. When the AGS is in the “Other” mode, manually turning the

generator off or on will not automatically disable the AGS system.