Ags: 08 ags tech menu, 0 using the me-rc remote – Magnum Energy AGS Network (ME-AGS-N) User Manual
Page 41

35
© 2012 Magnum Energy, Inc.
8.0 Using the ME-RC Remote
Info: When the RV mode is used and the AGS system feature is
required, the user will need to re-enable the AGS system each time
the generator is manually turned on or off.
Info: If the AGS is automatically disabled when using RV mode, the
AGS status displays “Lockout”.
• AGS
Rev – Displays the software revision of the connected AGS.
Info: The AGS accessory may display a “0.0” revision for several
reasons. Either the AGS is not installed, there is no communication
because of a bad or miswired network cable, the AGS is not pow-
ered, or the AGS is bad.
• AGS
Mode – This setting allows you to confi gure the AGS to comply
with RVIA standards¹. When the AGS is set to “RV”, the AGS is auto-
matically disabled any time the generator is manually turned on or off.
Select Other if your system is for a RV, or your requirements do not
need the AGS to be disabled should the generator be manually started/
stopped.
Default setting: AGS Mode = RV
Settings: RV, Other
AGS: 08 AGS TECH Menu
This menu displays meter data on the operating condition of the generator
and AGS, and has an AGS mode setting.
• Gen
Run – Displays the number of hours the generator has been cur-
rently running from an autostart condition. This menu does not deter-
mine run time when the generator has been manually started.
• AGS
VDC – Displays the battery voltage currently connected to the AGS
(on Terminals #3 and #4). This voltage is used to power the AGS and is
the voltage reading the 05 Start Volts setting is monitoring to determine
when to start.
• Temp – Displays the current temperature reading of the temperature
sensor and is the temperature the 04 Start Temp F setting is monitoring
to determine when to start. If the temperature sensor is not installed,
the display will either show a very high temperature value (122C/252F),
or “TS open” displays – depending on your remote revision.
Info: This menu is important when determining if the AGS is working
correctly, or for troubleshooting an AGS installation.
Info: For any fault mode displayed in the status menu, please refer
to Section 12.0 “ME-AGS-N Remote Troubleshooting” in this manual.
Note: AGS menus 03-07 were covered in Section 8.1.
Note¹ - RV manufacturers use the NFPA 1192 Standard on Recreational
Vehicles for installing an AGS system. This standard has a requirement that
states when the generator is manually turned on or off, the AGS system
must also be turned off. Selecting the “RV” setting satisfi es this requirement
by automatically disabling the AGS system when it senses that the generator
has been manually turned on or off. In installations where the requirement
to automatically disable the AGS system is not needed, the “Other” setting
can be chosen. When the AGS is in the “Other” mode, manually turning the