Data logging execution status, Data logging execution status -75 – Yaskawa MP3200 Troubleshooting Manual User Manual
Page 201

7.5 System Register Configuration and Error Status
Data Logging Execution Status
7-75
T
roubleshooting System Errors
Data Logging Execution Status
The data in these registers give the execution status of data logging.
Name
Register Addresses
Remarks
Data Logging Definition Existence SW24000
SB240000
0: Logging 1 definition does not exist,
1: Logging 1 definition exists
SB240001
0: Logging 2 definition does not exist,
1: Logging 2 definition exists
Data Logging Execution Status
SW24001
SB240010
0: Logging 1 is in progress,
1: Logging 1 is stopped
SB240011
0: Logging 2 is in progress,
1: Logging 2 is stopped
SB240012
0: Logging 3 is in progress,
1: Logging 3 is stopped
SB240013
0: Logging 4 is in progress,
1: Logging 4 is stopped
SB240014 to
SB240017
Reserved for system.
SB240018
0: Logging 1 is not waiting for trigger condition,
1: Logging 1 is waiting for trigger condition
SB240019
0: Logging 2 is not waiting for trigger condition,
1: Logging 2 is waiting for trigger condition
SB24001A
0: Logging 3 is not waiting for trigger condition,
1: Logging 3 is waiting for trigger condition
SB24001B
0: Logging 4 is not waiting for trigger condition,
1: Logging 4 is waiting for trigger condition
SB24001C
to SB24001F
Reserved for system.
Data Logging
Execution Sta-
tus Details
Logging 1
SL24002
File update counter
SQ24004
Latest record number
SW24008
Overrun counter
SW24009
Error code
0000 hex: No error,
0001 hex: No USB memory device
(at start of logging),
0002 hex: No USB memory device
(while logging is in progress),
0003 hex: Directory creation error,
0004 hex: File creation error,
0005 hex: File write error
SW24010 to SW24011
Reserved for system.
SW24012 to SW24043
Latest folder name
SW24044 to SW24065
Latest file name (includes extension such as
.csv)
Logging 2
SW24066 to SW24129
Same as Logging 1.
Logging 3
SW24130 to SW24193
Same as Logging 1.
Logging 4
SW24194 to SW24257
Same as Logging 1.
Reserved for system.
SW24258 to SW24321
−