7.5 System Register Configuration and Error Status
Module Information
7-41
T
roubleshooting System Errors
SVB-01
SVC-01
PO-01
MPU-01
Name
Register Address
Remarks
SVB-01 Information
SW00 + 0
Module ID (9195 hex)
SW00 + 1
Hardware version (BCD)
SW00 + 2
Software version (BCD)
SW00 + 3
Number of sub-slots (0001 hex)
SW00 + 4
SVB-01 Function Module ID (9115 hex)
SW00 + 5
SVB-01 Function Module Status
SW00 + 6
Reserved for system.
SW00 + 7
Reserved for system.
Name
Register Address
Remarks
SVC-01 Information
SW00 + 0
Module ID (9490 hex)
SW00 + 1
Hardware version (BCD)
SW00 + 2
Software version (BCD)
SW00 + 3
Number of sub-slots (0001 hex)
SW00 + 4
SVC-01 Function Module ID (9410 hex)
SW00 + 5
SVC-01 Function Module Status
SW00 + 6
Reserved for system.
SW00 + 7
Reserved for system.
Name
Register Address
Remarks
PO-01 Unit Information
SW00 + 0
Module ID (9390 hex)
SW00 + 1
Hardware version (BCD)
SW00 + 2
Software version (BCD)
SW00 + 3
Number of sub-slots (0001 hex)
SW00 + 4
PO Function Module ID (9310 hex)
SW00 + 5
PO Function Module Status
SW00 + 6
Reserved for system.
SW00 + 7
Reserved for system.
Name
Register Address
Remarks
MPU-01 Information
SW00 + 0
Module ID (82E0 hex)
SW00 + 1
Hardware version (BCD)
SW00 + 2
Software version (BCD)
SW00 + 3
Number of sub-slots (0001 hex)
SW00 + 4
MPU-01 Function Module ID (8260 hex)
SW00 + 5
MPU-01 Function Module Status
SW00 + 6
Reserved for system.
SW00 + 7
Reserved for system.