7.5 System Register Configuration and Error Status
Error Status for Individual Products
7-27
T
roubleshooting System Errors
263IF-01 Error Status
264IF-01 Error Status
(EtherNetIP)
F
8 7
0 (Bit number)
SW00+ 0
Error code (station error = 1)
Subslot (function) number (= 1)
F
0
(Bit number)
SW00 + 1
CNO
#16
···························
CNO#1
SW00 + 2
ST#32
···························
ST#17
SW00 + 3
ST#48
···························
ST#33
SW00 + 4
ST#64
···························
ST#49
SW00 + 5
Not used.
SW00 + 6
Not used.
SW00 + 7
Not used.
Table 7.10 EtherNet/IP Error Status Details
Item
Code
Remarks
Error code
0
No error
1
Station error
CNO#n
0
Communications normal
1
Communications error at station n
(EtherCAT-S)
F
8 7
0 (Bit number)
SW00 + 0
Error code (station error = 1)
Subslot (function) number (= 1)
(Bit number)
SW00 + 1
Reserved.
SW00 + 2
Communications error code
SW00 + 3
Communications phase
SW00 + 4
Data valid flags
SW00 + 5
Not used.
SW00 + 6
Not used.
SW00 + 7