1 overall configuration of the system registers, Overall configuration of the system registers -2 – Yaskawa MP3200 Troubleshooting Manual User Manual
Page 128

7.1 Overall Configuration of the System Registers
7-2
7.1
Overall Configuration of the System Registers
The indicators on the CPU Unit/CPU Module show the operating status and error status of the MP3000-
series Machine Controller. You can use the system (S) registers to obtain more detailed information on
errors. The contents of the system registers will allow you to isolate errors and implement corrections.
The following table shows the overall configuration of the system registers. Refer to the sections that are
given in the righthand column for details.
Register
Addresses
Contents
Reference
SW00000 to
SW00029
System Service Registers
−
SW00030 to
SW00049
System Status
SW00050 to
SW00079
System Error Status
System Error Status (page 7-9)
SW00080 to
SW00089
User Operation Error Status
User Operation Error Status in Ladder Programs
(page 7-11)
SW00090 to
SW00103
System Service Execution Status
Detailed User Operation Error Status (page 7-14)
SW00104 to
SW00109
Reserved for system.
−
SW00110 to
SW00189
Detailed User Operation Error Status
Detailed User Operation Error Status (page 7-14)
SW00190 to
SW00199
Reserved for system.
−
SW00200 to
SW00503
System I/O Error Status
System I/O Error Status (page 7-15)
SW00504 and
SW00505
Reserved for system.
−
SW00506 and
SW00507
Security Status
SW00508 to
SW00649
Reserved for system.
−
SW00650 to
SW00667
USB-related System Status
USB-related System Status (page 7-16)
SW00668 to
SW00693
Reserved for system.
−
SW00694 to
SW00697
Message Relaying Status
Message Relaying Status (page 7-16)
SW00698 to
SW00789
Interrupt Status
SW00790 to
SW00799
Reserved for system.
−
SW00800 to
SW01095
Module Information
Module Information (page 7-36)
SW01096 to
SW01410
Reserved for system.
−
SW01411 to
SW01442
MPU-01 Status
MPU-01 Module Status (page 7-40)
SW01443 to
SW03199
Reserved for system.
−
Continued on next page.