7.5 System Register Configuration and Error Status
Alarm History Information
7-71
T
roubleshooting System Errors
Details
The registers for the alarm history entries are structured as shown below. This example shows the system
register addresses for alarm history entry 1.
Alarm Details
Alarm details are given based on the alarm details format type.
• When the Alarm Details Format Type Is 1 (Operation Error)
Register Address
Remarks
Register Address
Example
SW + 0
SW16203
SW + 1
Alarm Code
SW16204
SW + 2
Alarm Details Format Type
1: Operation error
2: I/O error
3: Other error
SW16205
SW + 3
Year when alarm occurred
SW16206
SW + 4
Month when alarm occurred
SW16207
SW + 5
Day when alarm occurred
SW16208
SW + 6
Hour when alarm occurred
SW16209
SW + 7
Minutes when alarm occurred
SW16210
SW + 8
Seconds when alarm occurred
SW16211
SW + 9
Alarm details
The information depends on the alarm details format type.
SW16212
SW + 10
SW16213
SW + 11
SW16214
SW + 12
SW16215
SW + 13
SW16216
SW + 14
Reserved for system.
SW16217
SW + 15
Reserved for system.
SW16218
Register Address
Remarks
Register Address
Example
SW + 9
Error Drawing No.
SW16212
SW + 10
Calling Drawing No.
SW16213
SW + 11
Calling Drawing Step No.
SW16214
SW + 12
Reserved for system.
SW16215
SW + 13
Reserved for system.
SW16216
hex
01 to 09: Gives the slot number where the Module
in which the alarm occurred is mounted.
1 to 4: Gives the unit number of the Module in
which the alarm occurred is mounted.
1 to 7: Gives the Rack number where the Module in
which the alarm occurred is mounted.