User operation error code -1: operation, User operation error code -1: operation errors – Yaskawa MP3200 Troubleshooting Manual User Manual
Page 138

7.5 System Register Configuration and Error Status
User Operation Error Status in Ladder Programs
7-12
User Operation Error Code -1: Operation Errors
* The numeric values given in brackets [ ] are set by the system in the Changed A Register or Changed F Register before the oper-
ation error drawing is executed.
Error Code
Error Description
Operation When an Error Occurs
∗
Inte
ger Op
era
tions
0001 hex
Integer operation underflow
[-32768]
0002 hex
Integer operation overflow
[32767]
0003 hex
Integer operation division error
[The A register stays the same.]
0009 hex
Double-length integer operation underflow
[-2147483648]
000A hex
Double-length integer operation overflow
[2147483647]
000B hex
Double-length integer operation division error [The A register stays the same.]
000C hex
Quadruple-length integer operation underflow [-9223372036854775808]
000D hex
Quadruple-length integer operation overflow
[9223372036854775807]
000E hex
Quadruple-length integer operation division
error
[The A register stays the same.]
0101 hex to
010E hex
Integer operation error in Operation Error
Drawing
[The A register stays the same.]
Re
al N
umber Op
era
tions
0010 hex
Non-numerical integer storage error
Data is not stored. [00000]
0011 hex
Integer storage underflow
Data is not stored. [-32768]
0012 hex
Integer storage overflow
Data is not stored. [+32767]
0021 hex
Real number storage underflow
Data is not stored. [-1.0E+38]
0022 hex
Real number storage overflow
Data is not stored. [1.0E+38]
0023 hex
Real number operation division by zero error
Data is not stored. [F register stays the
same]
0030 hex
Invalid real number operation (non-numeric)
Data is not stored.
0031 hex
Real number operation exponent underflow
0.0
0032 hex
Real number operation exponent overflow
Maximum value
0033 hex
Real number operation division error (0/0)
Operation is not executed.
0034 hex
Real number storage exponent underflow
Stores 0.0.
0040 hex
to
0059 hex
Real number operation error in standard sys-
tem function
Operation is aborted and output is set to 0.0.
0040 hex: SQRT
0047 hex: EXP
004E hex: PD
0055 hex: SLAU
0041 hex: SIN
0048 hex: LN
004F hex: PID
0056 hex: REM
0042 hex: COS
0049 hex: LOG
0050 hex: LAG
0057 hex: RCHK
0043 hex: TAN
004A hex: DZA
0051 hex: LLAG
0058 hex: BSRCH
0044 hex: ASIN
004B hex: DZB
0052 hex: FGN
0059 hex: SORT
0045 hex: ACOS
004C hex: LIM
0053 hex: IFGN
−
0046 hex: ATAN
004D hex: PI
0054 hex: LAU