User Parameters

10-

23

H3-05

Multi-function analog input (termi-
nal A3)

2

L2-04

Voltage recovery time

0.3

H3-06 Gain (terminal A3)

100.0

L2-05

Undervoltage detection level

190

*7

H3-07 Bias (terminal A3)

0.0

L2-06

KEB deceleration time

0.0

H3-08

Multi-function analog input termi-
nal A2 function selection

2

L2-07

Momentary recovery time

0

*11

H3-09

Multi-function analog input termi-
nal A2 signal level selection

0

L2-08

Frequency reduction gain at KEB
start

100

H3-10 Gain (terminal A2)

100.0

L3-01

Stall prevention selection during
accel

1

H3-11 Bias (terminal A2)

0.0

L3-02

Stall prevention level during accel

150

H3-12 Analog input filter time constant

0.03

L3-03

Stall prevention limit during accel

50

H4-01 Monitor selection (terminal FM)

2

L3-04

Stall prevention selection during
decel

1

H4-02 Gain (terminal FM)

1.00

L3-05

Stall prevention selection during
running

1

H4-03 Bias (terminal FM)

0.0

L3-06

Stall prevention level during run-
ning

160

H4-04 Monitor selection (terminal AM)

3

L4-01

Speed agreement detection level

0.0

H4-05 Gain (terminal AM)

0.50

L4-02

Speed agreement detection width

2.0

H4-06 Bias (terminal AM)

0.0

L4-03

Speed agreement detection level
(+/-)

0.0

H4-07

Analog output 1 signal level selec-
tion

0

L4-04

Speed agreement detection width
(+/-)

2.0

H4-08

Analog output 2 signal level selec-
tion

0

L4-05

Operation when frequency refer-
ence is missing

0

H5-01 Station address

1F

L5-01

Number of auto restart attempts

0

H5-02 Communication speed selection

3

L5-02

Auto restart operation selection

0

H5-03 Communication parity selection

0

L6-01

Torque detection selection 1

0

H5-04

Stopping method after communi-
cation error

3

L6-02

Torque detection level 1

150

H5-05

Communication error detection
selection

1

L6-03

Torque detection time 1

0.1

H5-06 Send wait time

5

L6-04

Torque detection selection 2

0

H5-07 RTS control ON/OFF

1

L6-05

Torque detection level 2

150

H6-01 Pulse train input function selection

0

L6-06

Torque detection time 2

0.1

H6-02 Pulse train input scaling

1440

L7-01

Forward drive torque limit

200

H6-03 Pulse train input gain

100.0

L7-02

Reverse drive torque limit

200

H6-04 Pulse train input bias

0.0

L7-03

Forward regenerative torque limit

200

H6-05 Pulse train input filter time

0.10

L7-04

Reverse regenerative torque limit

200

H6-06 Pulse train monitor selection

2

L8-01

Protect selection for internal DB
resistor (Type ERF)

0

H6-07 Pulse train monitor scaling

1440

L8-02

Overheat pre-alarm level

95

L1-01

Motor protection selection

1

L8-03

Operation selection after overheat
pre-alarm

3

L1-02

Motor protection time constant

1.0

L8-05

Input open-phase protection selec-
tion

0

L1-03

Alarm operation selection during
motor overheating

3

L8-07

Output open-phase protection
selection

0

L1-04

Motor overheating operation selec-
tion

1

L8-09

Ground protection selection

1

L1-05

Motor temperature input filter time
constant

0.20

L8-10

Cooling fan control selection

0

L2-01

Momentary power loss detection

0

L8-11

Cooling fan control delay time

60

L2-02

Momentary power loss ridethru
time

0.1

*6

L8-12

Ambient temperature

45

L2-03

Min. baseblock time

0.5

L8-15

OL2 characteristics selection at
low speeds

1

Table 10.7 User Parameters (Continued)

No.

Name

Factory

Setting

Setting

No.

Name

Factory

Setting

Setting