User parameters for multi-function contact inputs are shown in the following tables.

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

H1-01

Multi-
Function
Digital Input
Terminal S3
Function
Selection

[Refer to table "

Multi-function

Contact Input Functions

" for

multi-function selections]

0 to 79

24

No

A

A

A

A

A

400H

Terminal S3 Sel

H1-02

Multi-
Function
Digital Input
Terminal S4
Function
Selection

0 to 79

14

No

A

A

A

A

A

401H

Terminal S4 Sel

H1-03

Multi-
Function
Digital Input
Terminal S5
Function
Selection

0 to 79

3 (0)

*

No

A

A

A

A

A

402H

Terminal S5 Sel

H1-04

Multi-
Function
Digital Input
Terminal S6
Function
Selection

0 to 79

4 (3)

*

No

A

A

A

A

A

403H

Terminal S6 Sel

H1-05

Multi-
Function
Digital Input
Terminal S7
Function
Selection

0 to 79

6 (4)

*

No

A

A

A

A

A

404H

Terminal S7 Sel

H1-06

Multi-
Function
Digital Input
Terminal S8
Function
Selection

0 to 79

8 (6)*

No

A

A

A

A

A

405H