Machine Protection

6-

39

Machine Protection

This section explains functions for protecting the machine.

‹

Reducing Noise and Leakage Current

The switching frequency of the Drive’s output transistor can be changed to reduce carrier noise and leakage
current from the motor.

„

Related Parameters

* 1. The setting range depends on the control method of the Drive.
* 2. The factory setting depends on the capacity of the Drive.
* 3. The setting range depends on the capacity of the Drive.
* 4. This parameter can be monitored or set only when 1 is set for C6-01 and F is set for C6-02.
* 5. Displayed in Quick Programming Mode when motor 2 is set for a multi-function input.

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

C6-02

Carrier
Frequency
Selection

Selects the number of pulses per second of
the output voltage waveform. Setting range
determined by C6-01 setting.
0: Low noise
1: Fc = 2.0 kHz
2: Fc = 5.0 kHz
3: Fc = 8.0 kHz
4: Fc = 10.0 kHz
5: Fc = 12.5 kHz
6: Fc = 15.0 kHz
OF: Program (Determined by the settings of
C6-03 thru C6-05)

1 to F

6

*2

No

Q

Q

Q

A

No

*5

CarrierFreq
Sel

C6-03

Carrier
Frequency
Upper Limit

Sets the carrier frequency upper limit and
lower limit in kHz units.
The carrier frequency gain is set as follows:

K is a coefficient that depends on the setting
of C6-03.
C6-03

≥ 10.0 kHz: K = 3

10.0 kHz > C6-03

≥ 5.0 kHz: K = 2

5.0 kHz > C6-03: K = 1
Maximum carrier frequency allowed when
C6-02 = F.
Note: Carrier frequency is set to C6-03
(upper limit) when operating in Vector
Control Mode.

C6-05 Sets the relationship of output

frequency to carrier frequency when

C6-02 = OF.

2.0

to

15.0

*3 *4

15.0

kHz

*2

No

A

A

A

A

No

CarrierFreq
Max

C6-04

Carrier
Frequency
Lower Limit

0.4

to

15.0

*3 *4

15.0

kHz

*2

No

A

A

No

No

No

CarrierFreq
Min

C6-05

Carrier
Frequency
Proportional
Gain

00

to

99

*4

00

No

A

A

No

No

No

CarrierFreq
Gain

C6-11

Carrier
Frequency
Selection for
Open Loop
Vector 2

Selects the carrier frequency during Vector
Control 2 wo/PG.
1: 2kHz (3-phase modulation)
2: 4kHz (3-phase modulation)
3: 6kHz (3-phase modulation)
4: 8kHz (3-phase modulation)

1 to 4

4

*2

No

No

*5

No

*5

No

*5

No

*5

Q

Carrier Freq
Sel

Carrier frequency

Output frequency x (C6-05) x K

(Max. output frequency)

Output

frequency