E1-04 maximum output frequency, E1-05 maximum output voltage, E1-06 base frequency – Yaskawa G7 Drive User Manual
Page 331: E1-07 mid output frequency a, E1-08 mid output voltage a, E1-09 minimum output frequency, E1-10 minimum output voltage, E1-11 mid output frequency b, E1-12 mid output voltage b
6
-114
E1-04 Maximum Output Frequency
Setting Range:
0.0 to 400.0Hz
Factory Default: 60.0Hz
E1-05 Maximum Output Voltage
Setting Range:
0.0 to 255.0V (200-240V Models)
0.0 to 510.0V (380-480V Models)
Factory Defaults: 230.0V (200-240V Models)
480.0V (380-480V Models)
E1-06 Base Frequency
Setting Range:
0.0 to 400.0Hz
Factory Default: 60.0Hz
E1-07 Mid Output Frequency A
Setting Range:
0.0 to 400.0Hz
Factory Default: 3.0Hz
E1-08 Mid Output Voltage A
Setting Range:
0.0 to 255.0V (200-240V Models)
0.0 to 510.0V (380-480V Models)
Factory Defaults: 12.6V (200-240V Models)
25.2V (380-480V Models)
E1-09 Minimum Output Frequency
Setting Range:
0.0 to 400.0Hz
Factory Default: 0.5Hz
E1-10 Minimum Output Voltage
Setting Range:
0.0 to 255.0V (200-240V Models)
0.0 to 510.0V (380-480V Models)
Factory Defaults: 2.3V (200-240V Models)
4.6V (380-480V Models)
E1-11 Mid Output Frequency B
Setting Range:
0.0 to 400.0Hz
Factory Default: 0.0Hz
E1-12 Mid Output Voltage B
E1-13 Base Voltage
Setting Range:
0.0 to 255.0V (200-240V Models)
0.0 to 510.0V (380-480V Models)
Factory Defaults: 0.0V (200-240V Models)
0.0V (380-480V Models)
To set up a custom V/f pattern, program the points shown in the diagram below using parameters E1-04 through
E1-13. Be sure that the following condition is true:: E1-09
≤ E1-07 ≤ E1-06 ≤ E1-11 ≤ E1-04