5

-78

n4-35

U1-48 Gain
Reduction
Coefficient

Setting this parameter to a
low value can improve
operation when acceleration
during low speeds or
regeneration needs to be
suppress. Be sure to keep this
setting high enough to avoid
causing a CF error.

0.50

to

1.50

1

No

No

No

No

No

A

5BAH

U1-48
Reduce Gain

n4-39

Flux Level at
Low
Frequency

Set this parameter to a small
value if the torque value is
relatively high compared to
the actual load that has been
set. Used during low speed
operation. (The magnitude of
the rated flux level as 100% )

50

to

150%

90%

No

No

No

No

No

A

5BEH

Flux Lvl
@LowFrq

n4-40

Current
Stability
Coefficient at
Low Speed

Reduce this setting if the
motor oscillates when
stopped with torque reference
at zero. Do not adjust this
setting more than is
necessary, verify the results
as changes are made.

0.01

to

1.00

0.5

No

No

No

No

No

A

5BFH

I Stabilize
Gain

n4-43

Speed
Estimation
Compensation
Gain

Adjust this parameter to
improve accuracy of speed
estimation under these
conditions.

1. Drive in torque control
mode.
2. Speed control is set to
d5-07.
3. Set b1-10=0
4. Make the following

adjustment:

Increase the value

when attempting to
estimate the speed of
the motor.

Caution: The motor may have

difficulty stopping
with small friction
loads. (even if the
torque reference is
set to zero).

0.00

to

2.00

0

No

No

No

No

No

A

5C2H

SpdEst Comp
Gain

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2